|
|
|
题名
|
作者
|
年代
|
出处
|
被引量
|
| 1 | Dental knowledge and awareness among grandparents显示文摘AIM: To investigate grandparent's knowledge and awareness about the oral health of their grandchildren. METHODS: Grandparents accompanying patients aged 4-8 years, who were living with their grandchildren and caring for them for a major part of the day, when both their parents were at work were included in the study. A 20-item questionnaire covering socio-demographic characteristics, dietary and oral hygiene practices was distributed to them. The sample comprised of 200 grandparents(59 males, 141 females). χ2 analysis and Gamma test of symmetrical measures were applied to assess responses across respondent gender and level of education.RESULTS: Oral health related awareness was found to be low among grandparents. In most questions asked, grandparents with a higher level of education exhibited a better knowledge about children's oral health. Level of awareness was not related to their gender. CONCLUSION: Oral hygiene and dietary habits are established during childhood. There is a great need for dental education of grandparents as they serve as role models for young children. | Jyoti Oberoi Rahul Kathariya Anup Panda Iti Garg Sonal Raikar | 2016 | World Journal of Clinical Pediatrics2016,5,1: | 1 |
| 2 | Reasearch on cascade multilevel inverter with single DC source by using three-phase transformem显示文摘 | Anup K Panda Yellasiri S | 2012 | Electrical Power and Energy Systems2012,40,1: | 1 |
| 3 | A Novel Triple-tied-cross-linked PV Array Configuration with Reduced Number of Cross-ties to Extract Maximum Power Under Partial Shading Conditions显示文摘Partial shadings cause output power reduction from Photovoltaic(PV)arrays due to mismatch losses.The selection of PV array configurations play a vital role in maximum power generation.This paper proposes a novel Triple-Tied-Cross-Linked(T-T-C-L)configuration to extract maximum power with a lesser number of cross ties than a Total-Cross-Tied(T-C-T)configuration.The performance of the proposed T-T-C-L configuration has been compared with various conventional PV array configurations,such as Series(S),Parallel(P),Series-Parallel(S-P),Bridge-Link(B-L),Honey-Comb(H-C),and T-C-T under Partial Shading Conditions(PSCs)by considering the 9×9 PV array.The PSCs considered are uneven row,column,diagonal,random,short&narrow,short&wide,long&narrow,long&wide shadings and uniform half module shading.The measures,such as open circuit voltage,short circuit current,maximum power,voltages and currents at maximum power,mismatch losses,fill factor and efficiency have been used for performance analysis of various configurations.From the results,it can be concluded that the performance of the proposed T-T-C-L configuration is optimal compared to other configurations. | Tejavathu Ramesh Kandipati Rajani Anup Kumar Panda | 2021 | CSEE Journal of Power and Energy Systems2021,7,3: | 1 |
| 4 | Deletions in chromosome 4 differentially associated with the development of cervical cancer: evidence of slit2 as a candidate tumor suppressor gene显示文摘 | Ratnesh Kumar Singh Dipanjana Indra Sraboni Mitra Ranajit Kumar Mondal Partha Sarathi Basu Anup Roy Susanta Roychowdhury Chinmay Kumar Panda | 2007 | Human Genetics2007,,1: | 1 |
| 5 | Analysis of cas-caded multilevel inverters for active harmonic filtering in distribu- tion networks 显示文摘 | Panda Anup Kumar Patnaik Sushree Sangita | 2015 | International Journal of Electrical Power and Energy Systems2015,,66: | 1 |
| 6 | Parallel inverter control using different conventional control methods and an improved virtual oscillator control method in a standalone microgrid显示文摘Partly because of advances in power electronic converters,the share of renewable energy in power generation is steadily increasing.The main medium of interface for integrating renewable energy sources to the utility grid is the power electronic inverter.Virtual oscillator control(VOC)is a time-domain approach for controlling parallel inverters in a standalone microgrid(MG).The concept is to simulate nonlinear deadzone oscillator dynamics in a system of invert-ers to ensure a stable AC MG in the absence of communication.VOC is a time-domain and self-synchronizing control-ler that simply requires the measurement of filter current,whereas traditional droop control and the virtual synchro-nous machine(VSM)require low pass filters for active and reactive power calculations.In this work,a particle swarm optimization(PSO)-based VOC method(VOC-PSO)is proposed,in which the parameters of the VOC are designed using the PSO algorithm.The system performance using droop,VSM,VOC,and VOC-PSO controllers are investigated using MATLAB and Opal-RT real-time digital simulator platforms.The results show that the proposed VOC-PSO gives improved performance over other control strategies.The efficacy of the proposed VOC-PSO control method is also demonstrated by the experimental results. | Vikash Gurugubelli Arnab Ghosh Anup Kumar Panda | 2022 | Protection and Control of Modern Power Systems2022,7,1: | 0 |