维普中文期刊产品整合服务
4篇 您的检索式:作者名="Shaleen Kumar"
    题名 作者 年代 出处 被引量
1Functional polymorphisms of cyclooxygenase-2 (COX-2) gene and risk for esophageal squmaous cell carcinoma显示文摘Rohit Upadhyay Meenu Jain Shaleen Kumar Uday Chand Ghoshal Balraj Mittal 2009Mutation Research - Fundamental and Molecular Mechanisms of Mutagenesis2009,,1:1
2Type IV-A choledochal cysts: a challenge显示文摘Richa Lal Shaleen Agarwal Rakesh Shivhare Ashok Kumar Sadiq S. Sikora Rajan Saxena Vinay K. Kapoor 2005Journal of Hepato - Biliary - Pancreatic Surgery2005,,2:1
3CYP1AI Mspl T/C Polymorphism in Esophageal Cancer: No Association and Risk Modulation显示文摘Meenu Jain Shaleen Kumar Uday C 2007Oncology Research2007,16,:1
4Investigation of lnter and Intra-fractional Uncertainties in Lung IMRT Delivery显示文摘Changes in the tumour position due to inter and intra-fractional motion introduce uncertainty in IMRT delivery. In this work, we experimentally evaluated the effect of inter and intra-fractional motion uncertainties in the IMRT delivery. A lung patient was planned with rive field dynamic IMRT for a total dose of60 Gy in 30 fractions using 6 MV photon beam at a dose rate of 400 MU/min. The plan was delivered on varian CL2100 CD linear accelerator with millennium 120 MLC for a single fraction and measured using IMRT Matri XX placed on Quasar motion platform, aligned with respect to isocentre for planar as well as point dose measurements. This measurement was summated for 30 fractions and taken as a reference. 30 measurements were performed for each inter-fractional, intra-fractional and combined effect. The setup errors(Mean+SD) used to simulate the inter-fractional displacements were RL:-0.10+0.27 mm, SI: 0.17+0.45 mm, AP:-0.04+0.38 mm and Rot: 0.02+0.86 degree. The intra-fractional motion was simulated using the motion platform parallel to the MLC leaf motion, for an amplitude of 1 cm and a period of 4 s. The planner fluence of inter, intra-fractional motion and combination of both was analyzed against the reference using gamma criteria of 3%/3 mm. Similarly, the point dose measurements were also compared. The maximum deviation in point dose during a single fraction was-3.8%, 3.1% and-5.9% for inter-fractional, intra-fractional and combined respectively. The same resulted in deviation of-0.4%,-0.3% and 0.1% respectively when summated for 30 fractions.The percentage of pixels failing the gamma criteria during a single fraction was28.0%, 16.4% and 28.5% for inter-fractional, intra-fractional and combined respectively. The same revealed 11.4%, 12.4% and 19.2% respectively when summated. Though the point dose deviations were nullified over 30 fractions, the planner fluence variation was observed to be considerable.Maria Das KJ Arpita Agarwal Yoganathan SA Gowtharu Raj D Shaleen Kumar 2017Chinese Journal of Biomedical Engineering(English Edition)2017,26,1:0
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费