维普中文期刊产品整合服务
12篇 您的检索式:作者名="Mohammad Zuber"
    题名 作者 年代 出处 被引量
1Antimi- c~bial and pilling evaluation of the modified cellulosic fabrics using polyurethane acrylate copolymers 显示文摘Shazia Tabasuma Mohammad Zuber Tahir Jamilb et d 2013International Journal of Biological Macromolecules2013,56,:1
2Synthesis and characterization of waterborne polyurethane acrylate copolymers显示文摘Misbah Sultan Haq Nawaz Bhatti Mohammad Zuber et a/ 2013Korean Journal of Chemical Engineering2013,30,2:1
3XRD studies of polyurethane elastomers based on chitin/1,4-butane diol blends显示文摘Khalid Mahmood Zia Ijaz Ahmad Bhatti Mehdi Barikani Mohammad Zuber Haq Nawaz Bhatti 2008Carbohydrate Polymers2008,,2:1
4Surface characteristics of chitinbased shape memory polyurethane elastomers 显示文摘Zia Khalid Mahmood Zuber Mohammad Barikani Mehdi 2009Colloids and Surfaces B: Biointerfaces2009,72,:1
5Surface characteristics of UV-irradiated chitin-based shape memory polyurethanes显示文摘Zia Khalid Mahmood Zuber Mohammad Mahboob Shahid 2010Carbohydrate Polymer2010,80,:1
6Investigation of Coronavirus Deposition in Realistic Human Nasal Cavity and Impact of Social Distancing to Contain COVID-19:A Computational Fluid Dynamic Approach显示文摘The novel coronavirus responsible for COVID-19 has spread to several countries within a considerably short period.The virus gets deposited in the human nasal cavity and moves to the lungs that might be fatal.As per safety guidelines by theWorld Health Organization(WHO),social distancing has emerged as one of the major factors to avoid the spread of infection.However,different guidelines are being followed across the countries with regards to what should be the safe distance.Thus,the current work is an attempt to understand the virus deposition pattern in the realistic human nasal cavity and also to find the impact of distance that could be termed as a safety measure.This study is performed usingComputationalFluid Dynamics as a solution tool to investigate the impact of COVID-19 deposition(i)On a realistic 3D human upper airway model and(ii)2D social distancing protocol for a distance of 0.6,1.2,1.8,and 2.4 m.The results revealed that the regional deposition flux within the nasal cavity was predominantly observed in the external nasal cavity and nasopharyngeal section.Frequent flushing of these regions with saltwater substitutes can limit contamination in healthy individuals.The safe distancing limit estimated with 1 m/s airflow was about 1.8 m.The extensive deposition was observed for distances less than 1.8 m in this study,emphasizing the fact that social distancing advisories are not useful and do not take into account the external dynamics associated with airflow.Mohammad Zuber John Valerian Corda Milad Ahmadi BSatish Shenoy Irfan Anjum Badruddin Ali E.Anqi Kamarul Arifin Ahmad S.M.Abdul Khader Leslie Lewis Mohammad Anas Khan Sarfaraz Kamangar 2020Computer Modeling in Engineering & Sciences2020,,12:1
7Recent developments in curcumin and curcumin based polymeric materials for biomedical applications: A review显示文摘Kashif Mahmood Khalid Mahmood Zia Mohammad Zuber Mahwish Salman Muhammad Naveed Anjum 2015International Journal of Biological Macromolecule2015,,:1
8Preparation of rich handles soft cellulosic fabric using amino silicone based softener:part Ⅱ:colorfastness properties显示文摘MOHAMMAD Zuber KHALID Mahmood Zia SHAZIA Tabassum 2011International Journal of Biological Macromolecules2011,,49:1
9Influence of Polyol Molecular Weight and Type on the Tack and Peel Properties of Waterborne Polyurethane Pressure-Sensitive Ac~esives 显示文摘Nadia Akram Robert S Gurney Mohammad Zuber 2013Macromolecular Reaction Engineering2013,7,10:1
10Preparation of rich handles soft cellulosic fabric using amino silicone based softener:part Ⅱ:colorfastness properties显示文摘MOHAMMAD Zuber KHALID Mahmood Zia SHAZIA Tabassum 2011International Journal of Biological Macromolecules2011,,49:1
11Fluid-Structure Interaction in Problems of Patient Specific Transcatheter Aortic Valve Implantation with and Without Paravalvular Leakage Complication显示文摘Paravalvular Leakage(PVL)has been recognized as one of the most dangerous complications in relation to Transcathether Aortic Valve Implantation(TAVI)activities.However,data available in the literature about Fluid Structure Interaction(FSI)for this specific problem are relatively limited.In the present study,the fluid and structure responses of the hemodynamics along the patient aorta model and the aortic wall deformation are studied with the aid of numerical simulation taking into account PVL and 100%TAVI valve opening.In particular,the aorta without valve(AWoV)is assumed as the normal condition,whereas an aorta with TAVI 26 mm for 100%Geometrical Orifice Area(GOA)is considered as the patient aorta with PVL complication.A 3D patient-specific aorta model is elaborated using the MIMICS software.Implantation of the identical TAVI valve of Edward SAPIEN XT 26(Edwards Lifes ciences,Irvine,California)is considered.An undersized 26 mm TAVI valve with 100%valve opening is selected to mimic the presence of PVL at the aortic annulus.The present research indicates that the existence of PVL can increase the blood velocity,pressure drop and WSS in comparison to normal conditions,thereby paving the way to the development of recirculation flow,thrombus formation,aorta wall collapse,aortic rupture and damage of endothelium.Adi Azriff Basri Mohammad Zuber Ernnie Illyani Basri Muhammad Shukri Zakaria Ahmad Fazli Abd Aziz Masaaki Tamagawa Kamarul Arifin Ahmad 2021Fluid Dynamics & Materials Processing2021,17,3:0
12Influence of postural changes on haemodynamics in internal carotid artery bifurcation aneurysm using numerical methods显示文摘Cerebral intracranial aneurysms are serious problems that can lead to stroke,coma,and even death.The effect of blood flow on cerebral aneurysms and their relationship with rupture are unknown.In addition,postural changes and their relevance to haemodynamics of blood flow are difficult to measure in vivo using clinical imaging alone.Computational simulations investigating the detailed haemodynamics in cerebral aneurysms have been developed in recent times not only to understand the progression and rupture but also for clinical evaluation and treatment.In the present study,the haemodynamics of a patient-specific case of a large aneurysm on the left side internal carotid bifurcation(LICA)and no aneurysm on the right side internal carotid bifurcation(RICA)was investigated.The simulation of these patient-specific models using fluid–structure interaction provides a valuable comparison of flow behavior between normal and aneurysm models.The influences of postural changes were investigated during standing,sleeping,and head-down(HD)position.Significant changes in flow were observed during the HD position and quit high arterial blood pressure in the internal carotid artery(ICA)aneurysm model was established when compared to the normal ICA model.The velocity increased abruptly during the HD position by more than four times(LICA and RICA)and wall shear stress by four times(LICA)to ten times(RICA).The complex spiral flow and higher pressures prevailing within the dome increase the risk of aneurysm rupture.Raghuvir Pai Ballambat Mohammad Zuber Shah Mohammed Abdul Khader Anurag Ayachit Kamarul Arifin bin Ahmad Rajanikanth ao Vedula Sevagur Ganesh Kamath Ibrahim Lutfi Shuaib 2022Visual Computing for Industry,Biomedicine,and Art2022,5,1:0
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费