维普中文期刊产品整合服务
5篇 您的检索式:作者名="Laszlo Modis"
    题名 作者 年代 出处 被引量
1Corneal biomechanical data and biometric parameters measured with Scheimpflug-based devices on normal corneas显示文摘AIM: To analyze the correlations between ocular biomechanical and biometric data of the eye,measured by Scheimpflug-based devices on healthy subjects.METHODS: Three consecutive measurements were carried out using the corneal visualization Scheimpflug technology(Cor Vis ST) device on healthy eyes and the 10 device-specific parameters were recorded.Pentacam HR-derived parameters(corneal curvature radii on the anterior and posterior surfaces;apical pachymetry;corneal volume;corneal aberration data;depth,volume and angle of the anterior chamber) and axial length(AL) from IOLMaster were correlated with the 10 specific CorV is ST parameters.RESULTS: Measurements were conducted in 43 eyes of 43 volunteers(age 61.24±15.72y).The 10 specific Cor Vis ST data showed significant relationships with corneal curvature radii both on the anterior and posterior surface,pachymetric data,root mean square(RMS) data of lower-order aberrations,and posterior RMS of higher-order aberrations and spherical aberration of the posterior cornea.Anterior chamber depth showed a significant relationship,but there were no significant correlations between corneal volume,anterior chamber volume,mean chamber angle or AL and the 10 specific CorV is ST parameters.CONCLUSION: Cor Vis ST-generated parameters are influenced by corneal curvature radii,some corneal RMS data,but corneal volume,anterior chamber volume,chamber angle and AL have no correlation with the biomechan-ical parameters.The parameters measured by CorV is ST seem to refer mostly to corneal properties of the eye.Gabor Nemeth Eszter Szalai Ziad Hassan Agnes Lipecz Zsuzsa Flasko Laszlo Modis 2017International Journal of Ophthalmology(English edition)2017,10,2:6
2Anterior chamber depth measurements in phakic and pseudophakic eyes: Pentacam versus ultrasound device显示文摘Gabor Nemeth Attila Vajas Bence Kolozsvari Andras Berta Laszlo Modis 2006Journal of Cataract & Refractive Surgery2006,,8:1
3Scheimpflug imaged corneal changes on anterior and posterior surfaces after collagen cross-linking显示文摘AIM:To compare the anterior and posterior corneal parameters before and after collagen cross-linking therapy for keratoconus.METHODS:Collagen cross-linking was performed in31 eyes of 31 keratoconus patients(mean age 30.6±8.9y).Prior to treatment and an average 7mo after therapy,Scheimpflug analysis was performed using Pentacam HR.In addition to corneal thickness assessments,corneal radius,elevation,and aberrometric measurements were performed both on anterior and posterior corneal surfaces.Data obtained before and after surgery were statistically analyzed.RESULTS:In terms of horizontal and vertical corneal radius,and central corneal thickness no deviations were observed an average 7mo after operation.Corneal higher order aberration showed no difference neither on anterior nor on posterior corneal surfaces.During follow-up period,no significant deviation was detected regarding elevation values obtained by measurement in mm units between the 3.0-8.0 mm-zones.CONCLUSION:Corneal stabilization could be observed in terms of anterior and posterior corneal surfaces,elevation and higher order aberration values 7mo after collagen cross-linking therapy for keratoconus.Ziad Hassan Laszlo Modis Eszter Szalai Andras Berta Gabor Nemeth 2014International Journal of Ophthalmology(English edition)2014,7,2:1
4Ocular biomechanical measurements on post- keratoplasty corneas using a Scheimpflug-based noncontact device显示文摘AIM: To analyse ocular biomechanical properties,central corneal thickness(CCT) and intraocular pressure(IOP) in post-keratoplasty eyes, as compared to normal subjects, with a new Scheimpflug-based technology.Moreover, biomechanical data were correlated with the size and age of the donor and recipient corneas.·METHODS: Measurements were conducted on 46 eyes of 46 healthy patients without any corneal pathology(age: 53.83 ±20.8y) and 30 eyes of 28 patients after penetrating keratoplasty(age: 49.43 ±21.34y). Ten biomechanical parameters, the CCT and IOP were recorded by corneal visualization Scheimpflug technology(Cor Vis ST) using high-speed Scheimpflug imaging. Keratometry values were also recorded using Pentacam HR system.Scheimpflug measurements were performed after 43.41 ±40.17mo(range: 11-128mo) after the keratoplasty and after 7.64±2.34mo(range: 5-14mo) of suture removal.·RESULTS: Regarding the device-specific biomechanical parameters, the highest concavity time and radius values showed a significant decrease between these two groups(P =0.01 and P <0.001). None of other biomechanical parameters disclosed a significant difference. The CCT showed a significant difference between post-keratoplasty eyes as compared to normal subjects(P =0.003) using the Cor Vis ST device. The IOP was within the normal range in both groups(P =0.84). There were no significant relationships between the keratometric data,the size of the donor and recipient, age of the donor and recipient and biomechanical properties obtained by Cor Vis ST.·CONCLUSION: The ocular biomechanics remain stable after penetrating keratoplasty according to the Cor Vis STmeasurements. Only two from the ten device-specific parameters have importance in the follow-up period after penetrating keratoplasty.Laszlo Modis Jr. Ziad Hassan Eszter Szalai Zsuzsanna Flasko Andras Berta Gabor Nemeth 2016International Journal of Ophthalmology(English edition)2016,9,2:1
5A survey of corneal changes caused by daily wear silicone hydrogel contact lenses显示文摘The examination of the effects of second generation lotra filcon B silicone hydrogel(SiH)lenses on the cornea when worn for three years of daily wear.Material and Methods:55 healthy patients were divided into two groups:current hydrogel contact lens wearers refitted with lotrafilcon B lenses(Group 1;28 patients)and neophyte contact lens wearers(Group 2;27 patients).Each patient's subjective eye comfort was measured with a self-administered questionnaire.The corneas were analyzed using contact specular microscope to measure corneal thickness and the endothelium before the SiH lenses werefitted after four weeks,one month,six months,one year,two years,and three years of lens wear.Results:Subjective complaints of patients in Group 1 were reduced;however patients in Group 2 experienced discomfort during the first two to four weeks of use.In Group 1,objective examinations identified a decrease in endothelial cell density.In Group 2,the endothelial cell density increased slightly in the first two years but decreased after three years.The results indicate that lotra filcon B slows down the deleterious effects of contact lenses.The coe±cient of variation significantly decreased after six months in Group 1(0.47 vs 0.44;p?0:049),whereas,in Group 2,the hexagonal cells improved significantly after one month(27.78 vs 28.25;p=0.025).Conclusion:Based on the subjects involved and the period of time under examination,it can be concluded that high-Dk SiH lenses support the physiological metabolism and functions of the cornea by improving oxygen provision.Beata Kettesy Julianna Vardai Andras Berta Laszlo Modis Jr. Adam Kemeny-Beke 2015Journal of Innovative Optical Health Sciences2015,8,6:0
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费