|
|
|
题名
|
作者
|
年代
|
出处
|
被引量
|
| 1 | A SURVEY ON SEMI-TENSOR PRODUCT OF MATRICES显示文摘当二个因素矩阵不遇见匹配状况的尺寸时,矩阵的半张肌产品是为盒子的常规矩阵产品的归纳。Itwas 大约十年以前第一求婚了。从那以后,它被开发了并且适用于几个不同领域。在这篇论文,我们将首先给简短介绍。然后分别地在它的应用程序上把调查给动态系统,到逻辑,到微分几何学,到抽象代数学。 | Daizhan CHENG Hongsheng QI Ancheng XUE | 2007 | Journal of Systems Science & Complexity2007,20,2: | 11 |
| 2 | On the mechanism and control for the ultra-low frequency oscillation in NY Power Grid with large-scale hydropower显示文摘The power grid with large proportion of hydropower may engage the ultra-low frequency oscillation (ULFO),which threatening the operation of system.To the NY Power Grid system,whose dimension is over thousands,this paper reveals the cause of ULFO with the phase portrait method,i.e.,lies in the saturation of the different limits of the governor system of the generators,in other words,the occurrence of limit cycle is due to the non-smooth bifurcation.And furthermore,it proposes two methods to suppress ULFO with the philosophy of destroying the condition of non-smooth bifurcation.In detail,first,the phenomenon of ULFO in NY Power Grid,the damping characteristics and the limits in the governor system of the hydropower units are presented.Second,based on the non-smooth bifurcation theory,the mathematical basis of the oscillation in the non-smooth system caused by the saturation of limits is introduced.And then,the non-oscillation and oscillation dynamic of the system corresponding to without/with limits in the governor system are analyzed.Furthermore,it discusses the influence of the saturation of single limit on the characteristics of ULFO with the phase portraits.Moreover,the phase portraits of the ULFO under different faults is analyzed,and it shows that the limiting saturation occurs with a large enough disturbance.Thus,the ULFO is resulting from the negative damping of generation and the saturation of multiple limits under a large enough disturbance.In addition,according to the above mechanism,two strategies to suppress the ULFO,i.e.,the governor parameters tuning and the fault strength relief are designed.The simulation shows the effectiveness of proposed strategies. | Ancheng XUE Jiawei WANG Chao ZHENG Joe H.CHOW Tianshu BI | 2019 | Control Theory and Technology2019,17,3: | 11 |
| 3 | On power system blackout modeling and analysis based on self-organized criticality显示文摘This paper makes a comprehensive survey on power system blackout modeling and analysis based on SOC (self-organized criticality). Firstly,a generalized SOC theory from the viewpoint of cybernetics is introduced. Then the evolution model of power system and its relative mathematical description,which serves as a concrete example of the proposed generalized SOC,are given. Secondly,five blackout models capturing various critical properties of power systems in different time-scales are listed. Finally,this paper analyzes SOC in power systems,such as,the revelation of criticalities of proposed models in both micro-scale and macro-scale which can be used to assess the security of power system,and cas-cading failures process. | MEI ShengWei XUE AnCheng ZHANG XueMin | 2008 | Science China(Technological Sciences)2008,51,2: | 10 |
| 4 | PERFORMANCE EVALUATION FOR DAMPING CONTROLLERS OF POWER SYSTEMS BASED ON MULTI-AGENT MODELS显示文摘This paper proposes a multi-layer multi-agent model for the performance evaluation of powersystems,which is different from the existing multi-agent ones.To describe the impact of the structureof the networked power system,the proposed model consists of three kinds of agents that form threelayers:control agents such as the generators and associated controllers,information agents to exchangethe information based on the wide area measurement system (WAMS) or transmit control signals tothe power system stabilizers (PSSs),and network-node agents such as the generation nodes and loadnodes connected with transmission lines.An optimal index is presented to evaluate the performance ofdamping controllers to the system's inter-area oscillation with respect to the information-layer topology.Then,the authors show that the inter-area information exchange is more powerful than the exchangewithin a given area to control the inter-area low frequency oscillation based on simulation analysis. | Ancheng XUE Yiguang HONG | 2009 | Journal of Systems Science & Complexity2009,22,1: | 3 |
| 5 | Failure analysis on China power grid based on power law显示文摘这篇论文尽最大努力涉及停电的机制从自我组织的 criticality 的观点的系统。由使用放大窗口变化(SWV ) 和重新可伸缩的范围统计(R/S ) 的二个评价算法,这篇论文尽最大努力学习停电数据系统在 1988-1997 期间。停电数据 of1994-1997 与自相关与一致很好的分析表演的结果。而且,停电概率对停电尺寸的功能展出幂定律分发,这被发现。 | Xiaofeng WENG Yiguang HONG Ancheng XUE Shengwei MEI | 2006 | 控制理论与应用(英文版)2006,4,3: | 1 |
| 6 | A Comprehensive Method to Compute the Controlling Unstable Equilibrium Point显示文摘 | Ancheng' Xue Shengwei Mei Bangpeng Xie | 2008 | Third International Conference on Electric Utility Deregulation and Restructuring and Power Technologies (DEPT)2008,,: | 1 |
| 7 | Failure analysis on China power grid based on power law显示文摘 | Weng Xiaofeng Hong Yiguang Xue Ancheng | 2006 | Journal of Control and Application2006,,3: | 1 |
| 8 | A PMU data recovering method based on preferred selection strategy显示文摘Nowadays, the technology of renewable sources grid-connection and DC transmission has a rapid development. And phasor measurement units(PMUs) become more notable in power grids, due to the necessary of real time monitoring and close-loop control applications. However, the PMUs data quality issue affects applications based on PMUs a lot. This paper proposes a simple yet effective method for recovering PMU data. To simply the issue, two different scenarios of PMUs data loss are first defined. Then a key combination of preferred selection strategies is introduced. And the missing data is recovered by the function of spline interpolation. This method has been tested by artificial data and field data obtained from on-site PMUs. The results demonstrate that the proposed method recovers the missing PMU data quickly and accurately. And it is much better than other methods when missing data are massive and continuous. This paper also presents the interesting direction for future work. | Zhiwei Yang Hao Liu Tianshu Bi Qixun Yang Ancheng Xue | 2018 | Global Energy Interconnection2018,1,1: | 1 |
| 9 | Correction of Time-varying PMU Phase Angle Deviation with Unknown Transmission Line Parameters显示文摘Phasor measurement units(PMUs)provide useful data for real-time monitoring of the smart grid.However,there may be time-varying deviation in phase angle differences(PADs)between both ends of the transmission line(TL),which may deteriorate application performance based on PMUs.To address that,this paper proposes two robust methods of correcting time-varying PAD deviation with unknown parameters of TL(ParTL).First,the phenomena of time-varying PAD deviation observed from field PMU data are presented.Two general formulations for PAD estimation are then established.To simplify the formulations,estimation of PADs is converted into the optimal problem with a single ParTL as the variable,yielding a linear estimation of PADs.The latter is used by second-order Taylor series expansion to estimate PADs accurately.To reduce the impact of possible abnormal amplitude data in field data,the IGG(Institute of Geodesy&Geophysics,Chinese Academy of Sciences)weighting function is adopted.Results using both simulated and field data verify the effectiveness and robustness of the proposed methods. | Ancheng Xue He Kong Feiyang Xu Junbo Zhao Naichao Chang Joe H.Chow Haiyan Hong | 2023 | CSEE Journal of Power and Energy Systems2023,9,1: | 0 |