|
|
|
题名
|
作者
|
年代
|
出处
|
被引量
|
| 1 | Survey of Technologies of Line Commutated Converter Based High Voltage Direct Current Transmission in China显示文摘This paper reviews the applications of line commutated converter based high voltage direct current transmission(LCC-HVDC)technologies in China,with a special focus on UHVDC technology developed in the last 10 years.The paper examines six specific aspects of areas—voltage increase,capacity upgrade,reliability improvement,engineering design innovation,equipment and materials innovation,and the R&D of next step.Subsequent advances in LCC-HVDC technologies in recent years are also discussed. | Zehong Liu Jun Yu Xianshan Guo Tao Sun Jin Zhang | 2015 | CSEE Journal of Power and Energy Systems2015,1,2: | 23 |
| 2 | The spontaneous emission of an excited atom embedded in photonic crystals with two atomic position-dependent bands显示文摘The spontaneous emission of an excited atom embedded in photonic crystals with two atomic position-dependent bands is investigated.The distribution of the density of states between two bands depends on the atomic position in a unit cell of the photonic crystal and is described with an atomic position-dependent parameter.The result shows that the emitted field and the time evolution of the upper-level population are affected by the atomic position and the gap width.The spontaneous emission spectrum in free space can be shifted and narrowed with the photonic reservoir and the gap width. | HUANG XianShan LIU HaiLian WANG Dong MO XuTao LIU HouTong | 2013 | Science China Chemistry2013,56,3: | 2 |
| 3 | Study on Deformation Characteristics of Deep Foundation Excavation in Soft-Soil and the Response of Different Retaining Configurations显示文摘 | Xianshan Liu Shaowei Liu | 2012 | Geotechnical and Geological Engineering2012,,2: | 1 |
| 4 | Control Strategy Optimization of Voltage Source Converter Connected to Various Types of AC Systems显示文摘Connecting the voltage source converters(VSCs) to various types of AC systems results in different operation characteristics and core problems associated with traditional control strategies. Therefore, it is necessary to optimize the control strategies of the VSCs according to the types of AC systems.For the VSCs connected to islanded renewable power plants, a voltage/frequency(V/f) droop control strategy is proposed to damp fluctuations of AC voltage and frequency in the island,which is vital for bipolar VSC control. In addition, a multibranch impedance equivalent method for renewable power plants is proposed, with which large-scale renewable power plants can be modeled accurately in the frequency domain to prevent wide-band oscillation. For the VSCs connected to strong AC systems, smart AC voltage and coordinated frequency transient control strategies are proposed, which can improve AC system transient stability. For the VSCs connected to weak AC systems, the relationship between the system stability and strength is analyzed, and then the control strategy of inner-loop control parameter optimization and outer-loop power limiting(if necessary) is proposed to improve the stability of the allied system. The proposed strategies are verified by both software simulation and field commissioning. | Zehong Liu Senior Member Xianshan Guo | 2021 | Journal of Modern Power Systems and Clean Energy2021,9,1: | 1 |
| 5 | Numerical simulation-based correction of relative permeability hysteresis in water-invaded underground gas storage during multi-cycle injection and production显示文摘By conducting relative permeability experiments of multi-cycle gas-water displacement and imbibition on natural cores,we discuss relative permeability hysteresis effect in underground gas storage during multi-cycle injection and production.A correction method for relative permeability hysteresis in numerical simulation of water-invaded gas storage has been worked out using the Carlson and Killough models.A geologic model of water-invaded sandstone gas storage with medium-low permeability is built to investigate the impacts of relative permeability hysteresis on fluid distribution and production performance during multi-cycle injection and production of the gas storage.The study shows that relative permeability hysteresis effect occurs during high-speed injection and production in gas storage converted from water-invaded gas reservoir,and leads to increase of gas-water transition zone width and thickness,shrinkage of the area of high-efficiency gas storage,and decrease of the peak value variation of pore volume containing gas,and then reduces the storage capacity,working gas volume,and high-efficiency operation span of the gas storage.Numerical simulations exhibit large prediction errors of performance indexes if this hysteresis effect is not considered.Killough and Carlson methods can be used to correct the relative permeability hysteresis effect in water-invaded underground gas storage to improve the prediction accuracy.The Killough method has better adaptability to the example model. | ZHU Sinan SUN Junchang WEI Guoqi ZHENG Dewen WANG Jieming SHI Lei LIU Xianshan | 2021 | Petroleum Exploration and Development2021,48,1: | 0 |
| 6 | An analysis method of injection and production dynamic transient flow in a gas field storage facility显示文摘A dynamic transient flow analysis method considering complex factors such as the cyclic injection and production history in a gas field storage facility was established in view of the limitations of the existing methods for transient flow analysis and the characteristics of the injection-production operation of strongly heterogeneous gas reservoirs, and the corresponding theoretical charts were drawn. In addition, an injection-production dynamic transient flow analysis model named 'three points and two stages' suitable for an underground gas storage(UGS) well with alternate working conditions was proposed. The 'three points' refer to three time points during cyclic injection and production, namely, the starting point of gas injection for UGS construction, the beginning and ending points of the injection-production analysis stage;and the 'two stages' refer to historical flow stage and injection-production analysis stage. The study shows that the dimensionless pseudo-pressure and dimensionless pseudo-pressure integral curves of UGS well flex downward in the early stage of the injection and production process, and the dimensionless pseudo-pressure integral derivative curve is convex during the gas production period and concave during the gas injection period, and the curves under different flow histories have atypical features. The new method present in this paper can analyze transient flow of UGS accurately. The application of this method to typical wells in Hutubi gas storage shows that the new method can fit the pressure history accurately, and obtain reliable parameters and results. | WANG Jieming LI Chun SUN Junchang TANG Ligen ZHONG Rong LIU Xianshan ZHENG Shaojing | 2022 | Petroleum Exploration and Development2022,49,1: | 0 |