|
|
|
题名
|
作者
|
年代
|
出处
|
被引量
|
| 1 | Endovascular treatment of blood blister-like aneurysms in the internal carotid artery using a Willis covered stent显示文摘Background Despite the current availability of flow diverter devices(FDD), problems remains regarding optimal endovascular treatment(EVT) for blood blister-like aneurysms(BBAs) of the internal carotid artery(ICA). Objective To evaluate the safety and efficacy of EVT of BBAs in the ICA with a Willis covered stent. Methods 20 consecutive patients(5 men and 15 women) with ruptured BBAs underwent EVT using a Willis covered stent in two institutions from March 2013 to March 2018. Clinical observations, angiographic characteristics, and procedural and follow-up outcomes were retrospectively evaluated. Results 20 consecutive patients(5 men and 15 women) with ruptured BBAs underwent EVT using a Willis covered stent in two institutions from March 2013 to March 2018. Clinical observations, angiographic characteristics, and procedural and follow-up outcomes were retrospectively evaluated. Conclusion Our initial results demonstrate that reconstructive EVT using a Willis covered stent provides a viable approach to treat ICA BBAs. However, an expanded clinical evaluation and larger cohort are needed to confirm the results. | Yi Gu Binxian Gu Yongdong Li Yueqi Zhu Haitao Lu Liming Wei Mo Chen Minhua Li Jieqing Wan Wu Wang | 2018 | Journal of Interventional Medicine2018,1,3: | 8 |
| 2 | Dual quaternion based virtual hand interaction modeling显示文摘Virtual hands play key roles in three-dimensional interaction in various virtual reality applications.However,their visual realism has seldom been seriously discussed in the community of human computer interaction,not to mention the challenging balance between their visual/motion realism and real-time performance.In this paper,a novel approach for virtual hand interaction modeling based on dual quaternion is proposed.Specifically,dual quaternion blending(DQB) is introduced as pseudo muscular layer of our virtual hand model instead of traditional linear blending(LB) and quaternion blending(QB) due to its advantages in muscular deformation.A framework for virtual hand interaction is proposed which supports both gesture interactions and 3D manipulations.Experimental results show that our proposed virtual hand interaction model is suitable for most virtual reality applications and achieves good visual/motion realism while maintains real-time performance. | CHEN WenFeng ZHU ShuJing WAN HuaGen FENG JieQing | 2013 | Science China(Information Sciences)2013,56,3: | 6 |
| 3 | Safety of endovascular therapy for symptomatic intracranial artery stenosis:a national prospective registry显示文摘Introduction The safety outcomes of endovascular therapy for intracranial artery stenosis in a real-world stetting are largely unknown.The Clinical Registration Trial of Intracranial Stenting for Patients with Symptomatic Intracranial Artery Stenosis(CRTICAS)was a prospective,multicentre,real-world registry designed to assess these outcomes and the impact of centre experience.Methods 1140 severe,symptomatic intracranial arterial stenosis(ICAS)patients treated with endovascular therapy were included from 26 centres,further divided into three groups according to the annual centre volume of intracranial angioplasty and stent placement procedures over 2 years:(1)high volume for≥25 cases/year;(2)moderate volume for 10–25 cases/year and(3)low volume for<10 cases/year.Results The rate of 30-day stroke,transient ischaemic attack or death was 9.7%(111),with 5.4%,21.1%and 9.7%in high-volume,moderate-volume and low-volume centres,respectively(p<0.05).Multivariable logistic regression confirmed high-volume centres had a significantly lower primary endpoint compared with moderate-volume centres(OR=0.187,95%CI:0.056 to 0.627;p≤0.0001),while moderate-volume and low-volume centres showed no significant difference(p=0.8456).Conclusion Compared with the preceding randomised controlled trials,this real-world,prospective,multicentre registry shows a lower complication rate of endovascular treatment for symptomatic ICAS.Non-uniform utilisation in endovascular technology,institutional experience and patient selection in different volumes of centres may have an impact on overall safety of this treatment. | Yabing Wang Tao Wang Adam Andrew Dmytriw Kun Yang Liqun Jiao Huaizhang Shi Jie Lu Tianxiao Li Yujie Huang Zhenwei Zhao Wei Wu Jieqing Wan Qinjian Sun Bo Hong Yongli Li Liyong Zhang Jianfeng Chu Qiong Cheng Yiling Cai Pengfei Wang Qi Luo Hua Yang Baijing Dong Yang Zhang Jun Zhao Zuoquan Chen Wei Li Xiaoxin Bai Weiwen He Xueli Cai Maimai Ti Osama O Zaidat | 2022 | Stroke & Vascular Neurology2022,7,2: | 3 |
| 4 | Comparison of the Pipeline embolisation device alone or combined with coiling for treatment of different sizes of intracranial aneurysms显示文摘Objectives The aim of this study was to compare complications and outcomes between intracranial aneurysms treated with the Pipeline embolisation device(PED)alone or with PED combined with coiling for different-sized aneurysms.Method Patients with aneurysms treated by PED were collected from the PED in China postmarket multicentre registry study.We performed a propensity match analysis to compare the efficacy and safety between PED alone and PED combined with coiling treatment,and then aneurysms were organised into three groups based on their size:small(≤7 mm),medium(≤15 mm to>7 mm)and large/giant(>15 mm).Complications and aneurysm occlusion rates in the aneurysm size groups were compared between PED alone and PED combined with coiling patients.Result A total of 1171 patients with 1322 aneurysms were included.All patients received clinical follow-up,while angiographic follow-up was available in 967 aneurysms.For small aneurysms,there was no difference in the aneurysm occlusion rate between two groups(79.1%vs 88.4%,respectively),while there was a significant increase in the ischaemic complication rate(8.3%vs 19.3%,respectively,p=0.0001).For medium and large/giant saccular aneurysms,PED combined with coiling significantly improved the occlusion rate(medium aneurysms:74.7%vs 88.8%,respectively,p<0.0001;large/giant saccular aneurysms:72.9%vs 86.9%,respectively,p=0.018),while there were no differences in the total complication rate.For large/giant non-saccular aneurysms,two groups showed no differences.Conclusion Use of the PED with adjunctive coils can significantly improve the occlusion rate of medium aneurysms,without increasing the total complication rate. | Chao Wang Bin Luo Tianxiao Li Aisha Maimaitili Guohua Mao Donglei Song Yunyan Wang Wenfeng Feng Yang Wang Huaizhang Shi Jieqing Wan Jianmin Liu Sheng Guan Yuanli Zhao Hongqi Zhang | 2022 | Stroke & Vascular Neurology2022,7,4: | 1 |