维普中文期刊产品整合服务
8篇 您的检索式:作者名="Yanmeng Yang"
    题名 作者 年代 出处 被引量
1Supercritical water oxidation of polyvinyl alcohol and desizing wastewater: Influence of NaOH on the organic decomposition显示文摘Polyvinyl alcohol is a refractory compound widely used in industry. Here we report supercritical water oxidation of polyvinyl alcohol solution and desizing wastewater with and without sodium hydroxide addition. However, it is difficult to implement complete degradation of organics even though polyvinyl alcohol can readily crack under supercritical water treatment. Sodium hydroxide had a significant catalytic effect during the supercritical water oxidation of polyvinyl alcohol. It appears that the OH ion participated in the C-C bond cleavage of polyvinyl alcohol molecules, the CO2-capture reaction and the neutralization of intermediate organic acids, promoting the overall reactions moving in the forward direction. Acetaldehyde was a typical intermediate product during reaction. For supercritical water oxidation of desizing wastewater, a high destruction rate (98.25%) based on total organic carbon was achieved. In addition, cases where initial wastewater was alkaline were favorable for supercritical water oxidation treatment, but salt precipitation and blockage issues arising during the process need to be taken into account seriously.Jie Zhang Shuzhong Wang Yang Guo Donghai Xu Yanmeng Gong Xingying Tang 2013Journal of Environmental Sciences2013,25,8:15
2Validation of Column-Averaged Dry-Air Mole Fraction of CO_2 Retrieved from OCO-2 Using Ground-Based FTS Measurements显示文摘In order to correctly use the column-averaged atmospheric CO_2 dry-air mole fraction(XCO_2) data in the CO_2 flux studies, XCO_2 measurements retrieved from the Orbiting Carbon Observatory-2(OCO-2) in 2015 were compared with those obtained from the global ground-based high-resolution Fourier Transform Spectrometer(FTS) participating in the Total Carbon Column Observing Network(TCCON). The XCO_2 retrieved from three observing modes adopted by OCO-2, i.e., nadir, target, and glint, were separately validated by the FTS measurements at up to eight TCCON stations located in different areas. These comparisons show that OCO-2 glint mode yields the best qualitative estimations of CO_2 concentration among the three operational approaches. The overall results regarding the glint mode show no obvious systematic biases. These facts may indicate that the glint concept is appropriate for not only oceans but also land regions. Negative systematic biases in nadir and target modes have been found at most TCCON sites. The standard deviations of XCO_2 retrieved from target and nadir modes within the observation period are similar, and larger than those from glint mode. We also used the FTS site in Beijing, China, to assess the OCO-2 XCO_2 in 2016. This site is located in a typical urban area, which has been absent in previous studies. Overall, OCO-2 XCO_2 agrees well with that from FTS at this site. Such a study will benefit the validation of the newly launched TanSat products in China.Yanmeng BI Qian WANG Zhongdong YANG Jie CHEN Wenguang BAI 2018Journal of Meteorological Research2018,32,3:3
3Validation results of NmF2 and hmF2 derived from ionospheric density profiles of GNOS on FY-3C satellite显示文摘The first Global Navigation Satellite System Occultation Sounder(GNOS) which is compatible of both Bei Dou System(BDS)and Global Positioning System(GPS) was successfully launched into orbit onboard the Feng Yun 3 C satellite(FY-3 C) on September 23, 2013, and it has already gathered a large amount of ionosphere radio occultation(RO) data so far. However, the detailed analysis and validation of GPS ionosphere RO data have not been done up to now. Therefore, this paper discusses the configuration of the FY-3 C GNOS, the methods and results of GPS ionosphere occultation processment, the quality analysis of the GPS ionosphere RO products, and the precision consistency between the GNOS GPS ionosphere RO product and ionosonde data. The peak electron density(Nm F2) correlation coefficient is 0.97, the corresponding standard deviation is 16.08%. The peak value altitude(hm F2) correlation coefficient is 0.89, and the corresponding standard deviation is 23.79 km. The in-orbit operation of GNOS provides a basis data set for the monitoring, forecasting and research of ionosphere's space weather.YANG GuangLin SUN YueQiang BAI WeiHua ZHANG XiaoXin LIU CongLiang MENG XiangGuang BI YanMeng WANG DongWei ZHAO DanYang 2018Science China(Technological Sciences)2018,61,9:2
4Fast CO_(2) Retrieval Using a Semi-Physical Statistical Model for the High-Resolution Spectrometer on the Fengyun-3D Satellite显示文摘China’s Fengyun-3D meteorological satellite launched in December 2016 carries the high-resolution greenhouse-gases absorption spectrometer(GAS)aimed at providing global observations of carbon dioxide(CO_(2)).To date,GAS is one of the few instruments measuring CO_(2) from the near-infrared spectrum.On orbit,the oxygen(O_(2))A band suffers a disturbance,and the signal-to-noise ratio(SNR)is significantly lower than the nominal specification.This leads to difficulties in the retrieval of surface pressure and hence a degradation of the retrieval of the column-averaged CO_(2) dry air mole fraction(XCO_(2))if a full physics retrieval algorithm is used.Thus,a fast CO_(2) inverse method,named semi-physical statistical algorithm,was developed to overcome this deficiency.The instrument characteristics,the semi-physical statistical algorithm,and the results of comparison with ground-based measurements over land were introduced in this paper.XCO_(2) can be obtained from three bands,namely,the O_(2) A,weak CO_(2),and strong CO_(2) bands,with compensation from the Medium Resolution Spectral Imager-2(MERSI-2)products,ECMWF Reanaly-sis v5(ERA-5)data,and Total Carbon Column Observing Network(TCCON)data.The eigenvectors of covariance matrices and the least square fits were used to derive retrieval coefficients and yield cloud-free solutions.In addition to the GAS radiance,some key factors necessary for the accurate estimations of XCO_(2) were also taken as input information(e.g.,air mass,surface pressure,and a priori XCO_(2)).The global GAS XCO_(2) restricted over land was compared against the simultaneously collocated observations from TCCON.The retrieval algorithm can mitigate the issue caused by the low SNR of the O_(2) A band to a certain extent.Overall,through site-by-site comparisons,GAS XCO_(2) agreed well with the average precision(1σ)of 1.52 ppm and bias of−0.007 ppm.The seasonal variation trends of GAS XCO_(2) can be clearly seen at TCCON sites on the 1-yr timescale.Yanmeng BI Peng ZHANG Zhongdong YANG Qian WANG Xingying ZHANG Chengbao LIU Pengmei XU Lizhou HOU Junyu KE Naiqiang ZHANG 2022Journal of Meteorological Research2022,36,2:2
5Oxidative degradation of lurgi coal gasification wastewater: Optimization using response surface methodology显示文摘Yuzhen Wang Shuzhong Wang Yang Guo Donghai Xu Yanmeng Gong Xingying Tang Jie Zhang 2014Sustainable Energy2014,,4:1
6Design of the first pilot scale plant of China for supercritical water oxidation of sewage sludge显示文摘Donghai Xu Shuzhong Wang Xingying Tang Yanmeng Gong Yang Guo Yuzhen Wang Jie Zhang 2011Chemical Engineering Research and Design2011,,2:1
7Secretive derived from hypoxia preconditioned mesenchymal stem cells promote cartilage regeneration and mitigate joint inflammation via extracellular vesicles显示文摘Secretome derived from mesenchymal stem cells (MSCs) have profound effects on tissue regeneration, which could become the basis of future MSCs therapies. Hypoxia, as the physiologic environment of MSCs, has great potential to enhance MSCs paracrine therapeutic effect. In our study, the paracrine effects of secretome derived from MSCs preconditioned in normoxia and hypoxia was compared through both in vitro functional assays and an in vivo rat osteochondral defect model. Specifically, the paracrine effect of total EVs were compared to that of soluble factors to characterize the predominant active components in the hypoxic secretome. We demonstrated that hypoxia conditioned medium, as well as the corresponding EVs, at a relatively low dosage, were efficient in promoting the repair of critical-sized osteochondral defects and mitigated the joint inflammation in a rat osteochondral defect model, relative to their normoxia counterpart. In vitro functional test shows enhancement through chondrocyte proliferation, migration, and matrix deposition, while inhibit IL-1β-induced chondrocytes senescence, inflammation, matrix degradation, and pro-inflammatory macrophage activity. Multiple functional proteins, as well as a change in EVs’ size profile, with enrichment of specific EV-miRNAs were detected with hypoxia preconditioning, implicating complex molecular pathways involved in hypoxia pre-conditioned MSCs secretome generated cartilage regeneration.Yanmeng Yang Yingnan Wu Dahou Yang Shu Hui Neo Nurul Dinah Kadir Doreen Goh Jian Xiong Tan Vinitha Denslin Eng Hin Lee Zheng Yang 2023Bioactive Materials2023,,9:0
8Inductorless CMOS Low Noise Amplifier for Multiband Application in 0.1–1.2 GHz显示文摘A 0.18 μm CMOS low noise amplifier(LNA) by utilizing noise-canceling technique was designed and implemented in this paper. Current-reuse and self-bias techniques were used in the first stage to achieve input matching and reduce power consumption. The core size of the proposed CMOS LNA circuit without inductor was only 128 μm 9226 μm. The measured power gain and noise figure of the proposed LNA were 20.6 and 1.9 dB,respectively. The 3-dB bandwidth covers frequency from 0.1 to 1.2 GHz. When the chip was operated at a supply voltage of 1.8 V, it consumed 25.69 mW. The high performance of the proposed LNA makes it suitable for multistandard low-cost receiver front-ends within the above frequency range.Guoxuan Qin Mengmeng Jin Guoping Tu Yuexing Yan Laichun Yang Yanmeng Xu Jianguo Ma 2017Transactions of Tianjin University2017,23,2:0
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费