维普中文期刊产品整合服务
5篇 您的检索式:作者名="Steven W Hetts"
    题名 作者 年代 出处 被引量
1Magnetic resonance imaging and multi-detector computed tomography assessment of extracellular compartment in ischemic and non-ischemic myocardial pathologies显示文摘Myocardial pathologies are major causes of morbidity and mortality worldwide. Early detection of loss of cellular integrity and expansion in extracellular volume(ECV) in myocardium is critical to initiate effective treatment. The three compartments in healthy myocardium are: intravascular(approximately 10% of tissue volume), interstitium(approximately 15%) and intracellular(approximately 75%). Myocardial cells, fibroblasts and vascular endothelial/smooth muscle cells represent intracellular compartment and the main proteins in the interstitium are types Ⅰ/Ⅲ collagens. Microscopic studies have shown that expansion of ECV is an important feature of diffuse physiologic fibrosis(e.g., aging and obesity) and pathologic fibrosis [heart failure, aortic valve disease, hypertrophic cardiomyopathy, myocarditis, dilated cardiomyopathy, amyloidosis, congenital heart disease, aortic stenosis, restrictive cardiomyopathy(hypereosinophilic and idiopathic types), arrythmogenic right ventricular dysplasia and hypertension]. This review addresses recent advances in measuring of ECV in ischemic and non-ischemic myocardial pathologies. Magnetic resonance imaging(MRI) has the ability to characterize tissue proton relaxation times(T1, T2, and T2*). Proton relaxation times reflect the physical and chemical environments of water protons in myocardium. Delayed contrast enhanced-MRI(DE-MRI) and multi-detector computed tomography(DE-MDCT) demonstrated hyper-enhanced infarct, hypo-enhanced microvascular obstruction zone and moderately enhanced peri-infarct zone, but are limited for visualizing diffuse fibrosis and patchy microinfarct despite the increase in ECV. ECV can be measured on equilibrium contrast enhanced MRI/MDCT and MRI longitudinal relaxation time mapping. Equilibrium contrast enhanced MRI/MDCT and MRI T1 mapping is currently used, but at a lower scale, as an alternative to invasive sub-endomyocardial biopsies to eliminate the need for anesthesia, coronary catheterization and possibility of tissue sampling error. Similar to delayed contrast enhancement, equilibrium contrast enhanced MRI/MDCT and T1 mapping is completely noninvasive and may play a specialized role in diagnosis of subclinical and other myocardial pathologies. DE-MRI and when T1-mapping demonstrated sub-epicardium, sub-endocardial and patchy mid-myocardial enhancement in myocarditis, Behcet's disease and sarcoidosis, respectively. Furthermore, recent studies showed that the combined technique of cine, T2-weighted and DE-MRI technique has high diagnostic accuracy for detecting myocarditis. When the tomographic techniques are coupled with myocardial perfusion and left ventricular function they can provide valuable information on the progression of myocardial pathologies and effectiveness of new therapies.Maythem Saeed Steven W Hetts Robert Jablonowski Mark W Wilson 2014World Journal of Cardiology2014,6,11:4
2Case 110: Nonossifying Fibroma 显示文摘Steven W Hetts SDH Russell W 2007Radiology2007,243,:1
3Anomalies of the Corpus allosum: An MR Analysis of thePhenotypic Spectrum of Associated Malformations显示文摘Steven W Hetts Elliott H Sherr tephanie Chao 2006Neuroradiology2006,187,11:1
4Magnetic resonance imaging characterization of circumferential and longitudinal strain under various coronary interventions in swine显示文摘AIM:To compare the acute changes in circumferential and longitudinal strain after exposing a coronary artery to various interventions in swine.METHODS:Percutaneous balloon angioplasty catheter was guided to location aid device(LAD)under X-ray fluoroscopy to create different patterns of ischemic insults.Pigs(n=32)were equally divided into 4 groups:controls,90 min LAD occlusion/reperfusion,LAD microembolization,and combined LAD occlusion/microembolization/reperfusion.Three days after interventions,cine,tagged and viability magnetic resonance imaging(MRI)were acquired to measure and compare left and right circumferential strain,longitudinal strain and myocardial viability,respectively.Measurements were obtained using HARP and semi-automated threshold method and statistically analyzed using unpaired t-test.Myocardial and vascular damage was characterized microscopically.RESULTS:Coronary microemboli caused greater impairment in l left ventricular(LV)circumferential strain and dyssynchrony than LAD occlusion/reperfusion despite the significant difference in the extent of myocardial damage.Microemboli also caused significant decrease in peak systolic strain rate of remote myocardium and LV dyssynchrony.Cine MRI demonstrated the interaction between LV and right ventricular(RV)at 3 d after interventions.Compensatory increase in RV free wall longitudinal strain was seen in response to all interventions.Viability MRI,histochemical staining and microscopy revealed different patterns of myocardial damage and microvascular obstruction.CONCLUSION:Cine MRI revealed subtle changes in LV strain caused by various ischemic insults.It also demonstrated the interaction between the right and left ventricles after coronary interventions.Coronary microemboli with and without acute myocardial infarction(AMI)cause complex myocardial injury and ventricular dysfunction that is not replicated in solely AMI.Mohammed SA Suhail Mark W Wilson Steven W Hetts Maythem Saeed 2013World Journal of Radiology2013,5,12:1
5Renal ablation using magnetic resonance-guided high intensity focused ultrasound: Magnetic resonance imaging and histopathology assessment显示文摘AIM: To use magnetic resonance-guided high intensity focused ultrasound(MRg-HIFU), magnetic resonance imaging(MRI) and histopathology for noninvasively ablating, quantifying and characterizing ablated renal tissue. METHODS: Six anesthetized/mechanically-ventilated pigs underwent single/double renal sonication(n = 24) using a 3T-MRg-HIFU(1.1 MHz frequency and 3000J-4400 J energies). T2-weighted fast spin echo(T2-W), perfusion saturation recovery gradient echo and contrast enhanced(CE) T1-weighted(T1-W) sequences were used for treatment planning, temperature monitoring, lesion visualization, characterization and quantification, respectively. Histopathology was conducted in excised kidneys to quantify and characterize cellular and vascular changes. Paired Student's t-test was used and a P-value < 0.05 was considered statistically significant.RESULTS: Ablated renal parenchyma could not be differentiated from normal parenchyma on T2-W or nonCE T1-W sequences. Ablated renal lesions were visible as hypoenhanced regions on perfusion and CE T1-W MRI sequences, suggesting perfusion deficits and necrosis. Volumes of ablated parenchyma on CE T1-W images invivo(0.12-0.36 cm3 for single sonication 3000 J, 0.50-0.84 cm3, for double 3000 J, 0.75-0.78 cm3 for single 4400 J and 0.12-2.65 cm3 for double 4400J) and at postmortem(0.23-0.52 cm3, 0.25-0.82 cm3, 0.45-0.68 cm3 and 0.29-1.80 cm3, respectively) were comparable. The ablated volumes on 3000 J and 4400 J double sonication were significantly larger than single(P < 0.01), thus, the volume and depth of ablated tissue depends on the applied energy and number of sonication. Macroscopic and microscopic examinations confirmed the locations and presence of coagulation necrosis, vascular damage and interstitial hemorrhage, respectively.CONCLUSION: Contrast enhanced MRI provides assessment of MRg-HIFU renal ablation. Histopathology demonstrated coagulation necrosis, vascular damage and confirmed the volume of damage seen on MRI.Maythem Saeed Roland Krug Loi Do Steven W Hetts Mark W Wilson 2016World Journal of Radiology2016,8,3:0
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费