维普中文期刊产品整合服务
4篇 您的检索式:作者名="S.Klima"
    题名 作者 年代 出处 被引量
1Field study results of a 3rd generation roof bolter canopy air curtain for respirable coal mine dust control显示文摘A 3rd generation roof bolter canopy air curtain(CAC)has been developed and constructed by J.H.Fletcher&Co.,Inc.As with the previous generation of the CAC,this design uses the principle of providing uniform airflow across the canopy area as recommended by the National Institute for Occupational Safety and Health.The new modifications include a plenum that is constructed of a single flat aluminum plate,smaller-diameter airflow openings,and a single row of perimeter nozzles designed to prevent mine air contaminated by respirable dust from entering the CAC protection zone.Field testing was conducted on this new 3rd generation design showing reductions in coal mine respirable dust exposure for roof bolter operators.Dust control efficiencies for the CAC for the left bolter operator(intake side)ranged from approximately 26%–60%,while the efficiencies for the CAC for the right bolter operator(return side)ranged from 3%to 47%.W.R.Reed M.Shahan S.Klima G.Ross K.Singh R.Cross T.Grounds 2020International Journal of Coal Science & Technology2020,7,1:4
2Laboratory results of a 3rd generation roof bolter canopy air curtain for respirable coal mine dust control显示文摘Testing was completed on an earlier roof bolter CAC that used slots to provide a perimeter airflow. NIOSH tested it due to its unique design that differed from canopies that provided uniform airflow. Based upon NIOSH recommendations from the earlier testing, a 3rd generation roof bolter CAC has been developed by J.H. Fletcher & Co. The changes to this CAC involve design modifications to the plenum outlets, using a single row of outlets on the perimeter and a different material for the plenum. This laboratory testing was a continuation of the original perimeter slotted CAC design. Using gravimetric and instantaneous sampling of respirable dust concentrations underneath and outside of the CAC. the laboratory testing was completed using three different blower fans that delivered differing airflows. The maximum plenum airflow velocities ranged from 2.34 to 3.64 m/s (460-716 fpm). Results showed plenum respirable dust concentrations ranging from 34.6% to 49.3% lower than respirable dust concentrations outside the plenum protection zone, thus showing an improvement in protection for the roof bolter operators.W.R.Reed G.J.Joy M.Shahan S.Klima G.Ross 2019International Journal of Coal Science & Technology2019,6,1:3
3A field study of a roof bolter canopy air curtain(2nd generation)for respirable coal mine dust control显示文摘A 2nd generation roof bolter canopy air curtain(CAC)design was tested by National Institute for Occupational Safety and Health(NIOSH)at a Midwestern underground coal mine.During the study,the roof bolter never operated downwind of the continuous miner.Using a combination of personal Data Rams(pDR)and gravimetric samplers,the dust control efficiency of the roof bolter CAC was ascertained.Performance evaluation was determined using three methods:(1)comparing roof bolter operator concentrations underneath the CAC to roof bolter concentrations outside the CAC,(2)comparing roof bolter operator concentrations underneath the CAC to the concentrations at the rear of the bolter,and finally,(3)using the gravimetric data directly underneath the CAC to correct roof bolter operator concentrations underneath the CAC and comparing them to the concentrations at the rear of the bolter.Method 1 dust control efficiencies ranged from 53.9%to 60.4%.Method 2 efficiencies ranged from 150.5%to 52.2%,and Method 3 efficiencies ranged from 40.7%to 91%.Reasons for negative and low dust control efficiencies are provided in this paper and include:incorrect sampling locations,large distance between CAC and operator,and contamination of intake air from line curtain.Low dust concentrations encountered during the testing made it difficult to discern whether differences in concentrations were due to the CAC or due to variances inherent in experimental dust measurement.However,the analyses,especially the Method 3 analysis,show that the CAC can be an effective dust control device.W.R.Reed S.Klima M.Shahan G.J.H.Ross K.Singh R.Cross T.Grounds 2019International Journal of Mining Science and Technology2019,29,5:0
4Using yttrium as an indicator to estimate total rare earth element concentration:a case study of anthracite-associated clays from northeastern Pennsylvania显示文摘This study demonstrated using yttrium(Y)as an indicator to estimate the total rare earth element and Y contents(REY)in coal-associated samples and to facilitate selection of samples with high REY assays in a fast and inexpensive manner.More than 10 anthracite-associated samples were collected from each of three Pennsylvanian sites(sites B,J and C)based on Thorium gamma ray logging suggesting high REY content.Several samples from each site were analyzed by ICP-MS to determine the rare earth distribution patterns and to establish the site-specific linear equations of Y and REY.The Y contents of the remaining samples were measured by a portable X-ray fluorescence analyzer,and the REY values were estimated based on the site-specific linear equation developed earlier.R-squared values above 0.70 were obtained for all the estimation equations from all three sites on both a whole sample basis and an ash basis.Previously,ash content has been widely used as an indicator of high REY content.This may not be applicable for a specific site.Site B in this study is an example where ash contents could not be statistically correlated with REY,so using Y for estimation is more applicable.The demonstrated sample screening process is suitable for samples from sites that share more similar distribution patterns(either MREY or LREY or HREY)as well as for samples from sites that share multiple distribution patterns(LREY/MREY/HREY)depending on the desirable accuracy.The demonstrated process lowers the analytical cost from$70 to 80 dollars per sample to$10-15 per sample while significantly reducing the processing time and acid consumption for ICP digestion.This is particularly true when a relatively large sample size is involved,for example,100 samples from one site analyzed by ICP-MS/OES.Xiaojing Yang Daniel Kozar Daniel Gorski Anthony Marchese James Pagnotti Rusty Sutterlin Mohammad Rezaee Mark S.Klima Sarma V.Pisupati 2020International Journal of Coal Science & Technology2020,7,4:0
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费