维普中文期刊产品整合服务
32篇 您的检索式:作者名="Pinit"
    题名 作者 年代 出处 被引量
1Efficacy of leukocyte esterase dipstick test as a rapid test in diagnosis of spontaneous bacterial peritonitis显示文摘AIM: To evaluate the efficacy of dipstick test in diagnosis of spontaneous bacterial peritonitis (SBP) in cirrhotic patients who underwent abdominal paracentesis based on the locally available dipstick test. METHODS: There were 200 consecutive samples from cirrhotic patients who underwent abdominal paracentesis. Urine dipstick (Combur10 Test?M, Roche, Mannheim, Germany) was used as a screening test. A manual cell count with differential study was done in all samples by experienced technicians. The polymorphonuclear (PMN) cell count more than 250 cells/mm3 was used as a diagnostic cut off level. One to three plus dipstick results were used as cut off levels for a positive result. The dipstick test results had to be agreed by three experienced readers. The sensitivity, specificity, positive and negative predictive values and accuracy of two different colorimetric cut off scales (1+ and 2+) were calculated and compared. RESULTS: The prevalence of SBP diagnosed by manual cell count was 21.0%. There were 128 specimens that had a true negative result by dipstick. The sensitivity, specificity, positive and negative predictive values and accuracy of 1+ and 2+ cut off scale to diagnose SBP were 88%, 81%, 55%, 96% and 83% respectively, and 63%, 96%, 82%, 81% and 89% respectively. CONCLUSION: Dipstick test can be used as a rapid test for screening of SBP. The higher cut off colorimetric scale has a better specificity and positive predictive value but a lower sensitivity.Rungsun Rerknimitr Worawut Rungsangmanoon Pradermchai Kongkam Pinit Kullavanijaya 2006World Journal of Gastroenterology2006,12,44:8
2Non-sequential narrow band imaging for targeted biopsy and monitoring of gastric intestinal metaplasia显示文摘AIM: To evaluate the efficacy of non-sequential narrow band imaging (NBI) for a better recognition of gastric intestinal metaplasia (GIM). METHODS: Previously diagnosed GIM patients underwent targeted biopsy from areas with and without GIM, as indicated by NBI, twice at an interval of 1 year. The authors compared the endoscopic criteria such as light blue crest (LBC), villous pattern (VP), and large long crest (LLC) with standard histology. The results from two surveillance endoscopies were compared with histology results for sensitivity, specif icity, positive predic-tive value (PPV), negative predictive value (NPV), and likelihood ratio of positive test (LR+). The number of early gastric cancer cases detected was also reported. RESULTS: NBI targeted biopsy was performed in 38 and 26 patients during the first and second surveillance endoscopies, respectively. There were 2 early gastric cancers detected in the first endoscopy. No cancer was detected from the second study. Surgical and endoscopic resections were successfully performed in each patient. Sensitivity, specifi city, PPV, NPV, and LR+ of all 3 endoscopic criteria during the first/second surveillances were 78.8%/91.3%, 82.5%/89.1%, 72.8%/77.8%, 86.8%/96.1, and 4.51/8.4, respectively. LBC provided the highest LR+ over VP and LLC. CONCLUSION: Non-sequential NBI is useful for GIM targeted biopsy. LBC provides the most sensitive reading. However, the optimal duration between two surveillances requires further study.Rungsun Rerknimitr Boonlert Imraporn Naruemon Klaikeaw Wiriyaporn Ridtitid Sukprasert Jutaghokiat Yuwadee Ponauthai Pradermchai Kongkam Pinit Kullavanijaya 2011World Journal of Gastroenterology2011,17,10:7
3Forward-viewing radial-array echoendoscope for staging of colon cancer beyond the rectum显示文摘AIM:To evaluate feasibility of the novel forward-viewing radial-array echoendoscope for staging of colon cancer beyond rectum as the first series.METHODS:A retrospective study with prospectively entered database.From March 2012 to February 2013,a total of 21 patients(11 men)(mean age 64.2 years)with colon cancer beyond the rectum were recruited.The novel forward-viewing radial-array echoendoscope was used for ultrasonographic staging of colon cancer beyond rectum.Ultrasonographic T and N staging were recorded when surgical pathology was used as a gold standard.RESULTS:The mean time to reach the lesion and the mean time to complete the procedure were 3.5 and 7.1min,respectively.The echoendoscope passed through the lesions in 13 patients(61.9%)and reached the cecum in 10 of 13 patients(76.9%).No adverse events were found.The lesions were located in the cecum(n=2),ascending colon(n=1),transverse colon(n=2),descending colon(n=2),and sigmoid colon(n=14).The accuracy rate for T1(n=3),T2(n=4),T3(n=13)and T4(n=1)were 100%,60.0%,84.6%and 100%,respectively.The overall accuracy rates for the T and N staging of colon cancer were 81.0%and52.4%,respectively.The accuracy rates among traversable lesions(n=13)and obstructive lesions(n=8)were 61.5%and 100%,respectively.endoscopic ultrasound and computed tomography had overall accuracy rates of 81.0%and 68.4%,respectively.CONCLUSION:The echoendoscope is a feasible staging tool for colon cancer beyond rectum.However,accuracy of the echoendoscope needs to be verified by larger systematic studies.Pradermchai Kongkam Sittikorn Linlawan Satimai Aniwan Narisorn Lakananurak Suparat Khemnark Chucheep Sahakitrungruang Jirawat Pattanaarun Supakij Khomvilai Naruemon Wisedopas Wiriyaporn Ridtitid Manoop S Bhutani Pinit Kullavanijaya Rungsun Rerknimitr 2014World Journal of Gastroenterology2014,20,10:5
4一种新型廉价、环境友好、结构稳定且具有大离子通道的钾离子电池正极材料显示文摘得益于钾的地壳丰度及其与锂的化学相似性,钾离子电池有望应用于大规模储能领域.目前,钾离子电池的性能尚不能满足实用需求,主要原因在于缺乏合适的正极材料.基于硫酸根的强诱导效应和草酸体系制备亚铁化合物的优势,本文制备了一种新型廉价、环境友好且稳定的储钾正极材料K_(4)Fe_(3)(C_(2)O_(4))_(3)(SO_(4))_(2).其独特的二维层状晶体结构具有3.379Å的层间距,且层内具有4.576×6.846Å的大环.根据第一性原理计算,该结构有利于钾离子的可逆迁移,且体积变化仅为6.4%.不同充放电态样品的同步辐射X射线吸收光谱和XRD、半电池以及全电池的电化学表征证实了其优异的电化学可逆性和结构稳定性.通过成分调控、掺杂、结构优化等策略,K_(4)Fe_(3)(C_(2)O_(4))_(3)(SO_(4))_(2)正极材料的电化学性能有望进一步提升.因此,本工作为廉价、环保的储钾正极材料提供了一种新的稳定晶体模型.王伟科 季必发 姚文娇 张馨元 郑勇平 周小龙 Pinit Kidkhunthod 何海燕 唐永炳 2021Science China Materials2021,64,5:3
5Role of digital chromoendoscopy in detecting minimal change esophageal reflux disease显示文摘Endoscopy is a widely used diagnostic tool to detect reflux esophagitis.Although its specificity was reported to be excellent at 90%-95%,its sensitivity was only 50%.Therefore,it is quite difficult to detect these lesions under the standard white light endoscopy especially in patients with minimal change esophageal reflux disease(MERD).In recent years,endoscopic technologies have evolved tremendously;these include high resolution and magnification digital chromoendoscopy.These technologies are useful practically for detecting various subtle lesions along the gastrointestinal tract starting from esophagus to colon.Currently,these technologies can be classified in 2 systems;pre-processed system(NBI,Olympus)and post processed system(FICE and i-SCAN,Fujinon and Pentax respectively).Over a few years,there have been many emerging publications on the benefit of these systems on MERD detection.The overall sensitivities to diagnose MERD were reported as much better than controls.However,large,multi-center and randomized controlled studies comparing these new imaging modalities with the conventional white light chromoendoscopy are warranted to validate its accuracy.Standard,simple and precise endoscopic reading criteria for the identification of MERD are also required.Roongruedee Chaiteerakij Rungsun Rerknimitr Pinit Kullavanijaya 2010World Journal of Gastrointestinal Endoscopy2010,2,4:2
6Advances in diagnostic endoscopy for duodenal, including ampullary, adenoma显示文摘Rapat Pittayanon Boonlert Imraporn Rungsun Rerknimitr Pinit Kullavanijaya 2014Digestive Endoscopy2014,,:2
7Digitally whole-field analysis of isoclinic parameter in photoelasticity by four-step color phase-shifting technique显示文摘Pinit P Umezaki E 2007Opt Laser Eng2007,45,7:1
8Digitally whole-field analysis of isoclinic parameter in photoelasticity by four-step color phase-shifting technique显示文摘P. Pinit E. Umezaki 2007Optics and Lasers in Engineering2007,,7:1
9Differences in characteristics of colorectal neoplasm between young and elderly Thais显示文摘AIM: To analyze the differences of clinical characteristics of colorectal neoplasm including polyps between the elderly and young Thai patients.METHODS: Colonoscopy database from December 2000 to October 2004 was retrospectively analyzed. There were 1822 eligible patients who underwent colonoscopy (with a mean age of 56.6 years). Patients were classified into two groups: the older age group (aged ≥ 60 years; n = 989) and the younger age group (aged < 60 years; n = 833). Data were recorded on age, colonoscopic indications, tumor location, colonoscopic findings and their related histological findings. RESULTS: Colorectal malignancy related lesions were more often found in the older age group (21%) than in the younger age group (12%). Left-sided lesions were detected more commonly than right-sided in both age groups in approximately two-thirds of all cases. Hematochezia showed greater association with left-sided lesions in the elderly. No relationship was found between age and neoplasm staging and severity.CONCLUSION: The chance of detecting colorectal neoplasm by colonoscopy was higher in the elderly than in the young Thais. However, both groups had the lesions predominantly located in the left side.Rungsun Rerknimitr Winudda Ratanapanich Pradermchai Kongkam Pinit Kullavanijaya 2006World Journal of Gastroenterology2006,12,47:1
10Molecular grafting towards high-fraction active nanodots implanted in N-doped carbon for sodium dual-ion batteries显示文摘Sodium-based dual-ion batteries(Na-DIBs) show a promising potential for large-scale energy storage applications due to the merits of environmental friendliness and low cost.However,Na-DIBs are generally subject to poor rate capability and cycling stability for the lack of suitable anodes to accommodate large Na+ ions.Herein,we propose a molecular grafting strategy to in situ synthesize tin pyrophosphate nanodots implanted in N-doped carbon matrix(SnP_(2)O_(7)@N-C),which exhibits a high fraction of active SnP_(2)O_(7) up to 95.6 wt% and a low content of N-doped carbon(4.4 wt%) as the conductive framework.As a result,this anode delivers a high specific capacity400 mAh g^(-1) at 0.1 A g^(-1),excellent rate capability up to 5.0 A g^(-1) and excellent cycling stability with a capacity retention of 92% after 1200 cycles under a current density of1.5 A g^(-1).Further,pairing this anode with an environmentally friendly KS6 graphite cathode yields a SnP_(2)O_(7)@N-C||KS6 Na-DIB,exhibiting an excellent rate capability up to 30 C,good fast-charge/slow-discharge performance and long-term cycling life with a capacity retention of96% after 1000 cycles at 20 C.This study provides a feasible strategy to develop high-performance anodes with high-fraction active materials for Na-based energy storage applications.Sainan Mu Qirong Liu Pinit Kidkhunthod Xiaolong Zhou Wenlou Wang Yongbing Tang 2021National Science Review2021,8,7:1
11Digitally whole-field analysis of isoelinic parameter in photoelasticity by four-step color phase-shifting technique 显示文摘Pinit P Umezaki E 2007Optics and Lasers in Engineering2007,45,7:1
12Digitally whole-field analysis of isoclinic parameter in photoelasticity by four-step color phase-shifting technique显示文摘Pinit P Umezaki E 2007Optics and Lasers in Engineering2007,45,:1
13Digitally whole-field analysis of isoclinic parameter in photoelasticity by four-step color phase shifting technique显示文摘Pinit P Umezaki E 2007Optics and Laser in Engineering2007,45,7:1
14Digitally whole-field analysis of isoclinic parameter in photoelasticity by four- step color phase-shifting technique 显示文摘Pinit P Umezaki E 2007Optics and Lasers in Engineering2007,45,7:1
15Result of Endoscopic Biliary Drainage in Hilar Cholangiocarcinoma显示文摘Rungsun Rerknimitr Nusont Kladcharoen Varocha Mahachai Pinit Kullavanijaya 2004Journal of Clinical Gastroenterology2004,,6:1
16Outcome of second interventions for occluded metallic stents in patients with malignant biliary obstruction显示文摘Wiriyaporn Ridtitid Rungsun Rerknimitr Akkawat Janchai Pradermchai Kongkam Sombat Treeprasertsuk Pinit Kullavanijaya 2010Surgical Endoscopy2010,,9:1
17Trimming a Metallic Biliary Stent Using an Argon Plasma Coagulator显示文摘Rungsun Rerknimitr Pisit Naprasert Pradermchai Kongkam Pinit Kullavanijaya 2007CardioVascular and Interventional Radiology2007,,3:1
18Result of Endoscopic Biliary Drainage in Hilar Cholangiocarcinoma显示文摘Rungsun Rerknimitr Nusont Kladcharoen Varocha Mahachai Pinit Kullavanijaya 2004Journal of Clinical Gastroenterology2004,,:1
19Microleakage-Full crowns and the Dental Pulp显示文摘Melvin Goldman Pinit Laosonthom Robert R White 1992J Endodon1992,18,10:1
20Digitally whole-field analysis ofisoclinic parameter in photoelasticity by four-step colorphase-shifting technique 显示文摘Pinit P Umezaki E 2007Optics and Lasers inEngineering2007,45,7:1
返回顶部 每页显示:
共2页 首页 上一页 第1页 下一页 末页 /2 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费