维普中文期刊产品整合服务
8篇 您的检索式:作者名="HongDa Fang"
    题名 作者 年代 出处 被引量
1Synthesis of a novel ternary HA/Fe-Mn oxides-loaded biochar composite and its application in cadmium(Ⅱ) and arsenic(Ⅴ) adsorption显示文摘Cadmium (Cd) and arsenic (As) are two of the most toxic elements.However,the chemical behaviors of these two elements are different,making it challenging to utilize a single adsorbent with high adsorption capacity for both Cd(Ⅱ) and As(Ⅴ) removal.To solve this problem,we synthesized HA/Fe-Mn oxides-loaded biochar (HFMB),a novel ternary material,to perform this task,wherein scanning electron microscopy (SEM) combined with EDS (SEM-EDS) was used to characterize its morphological and physicochemical properties.The maximum adsorption capacity of HFMB was 67.11 mg/g for Cd(Ⅱ) and 35.59 mg/g for As(Ⅴ),which is much higher compared to pristine biochar (11.06 mg/g,0 mg/g for Cd(Ⅱ) and As(Ⅴ),respectively).The adsorption characteristics were investigated by adsorption kinetics and the effects of the ionic strength and pH of solutions.X-ray photoelectron spectroscopy (XPS) and Fourier-transform infrared spectroscopy (FT-IR) revealed that chelation and deposition were the adsorption mechanisms that bound Cd(Ⅱ) to HFMB,while ligand exchange was the adsorption mechanism that bound As(Ⅴ).Jianhua Guo Changzhou Yan Zhuanxi Luo Hongda Fang Shugang Hu Yinglan Cao 2019Journal of Environmental Sciences2019,31,11:10
2The Remote Sensing of Sargassum on Daya BayLi Tiefang (Center for Remote Sensing, Zhongshan University) Liu Huai, Fang Hongda (South China Sea Marine Environmental Monitoring Center, SOA) Dong Yuguo (Guangzhou Institute of New Techniques in Geology, Academic Sinica) 1990遥感信息1990,12,A02:5
3A novel compression framework using energy-sensitive QRS complex detection method for a mobile ECG显示文摘Dear editor,Novel wearable applications provide improved data compression for reduced power consumption [1, 2];however, real-time monitoring of a single source electrocardiogram (ECG) signal leads to extended data usage of 2.77 GB per day. The Q wave, R wave.Sikai WANG Bo PANG Ming LIU Xu ZHANG Fang YUAN Wentao SHEN Hongda CHEN 2019Science China(Information Sciences)2019,62,6:3
4An intraoperative lumbar neurological force monitoring system with high-density flexible pressure sensor array显示文摘In the surgery of lumbar disc herniation(LDH),the nerve root retractor is used to pull the nerve root to prevent damage.The traditional medical nerve root retractor cannot quantify the force on the nerve root.In order to improve the nerve root retractor,this paper proposes an intraoperative lumbar neurological force monitoring system.The core module of this system is the improved nerve root retractor equipped with the high density flexible pressure sensor array.The high density microneedle array and multiple pressure detection units are used in the pressure sensor to realise sensitive pressure monitoring in a narrow surgical operation area.The sensing area is 4 mm×17 mm,including 6 detection units.The sensitivity of sensor is 67.30%/N in the range of 0-5 N.This system is used for in vitro animal experiments,which can continuously detect pressure.张琪 Zhang Xu Li Caili Liu Jianchao Liu Ming Yuan Fang Chen Hongda 2020High Technology Letters2020,26,4:2
532-site microelectrode modified with Pt black for neural recording fabricated with thin-film silicon membrane显示文摘Multi-electrode array is an important tool in the study of neural-network,cognition,remembrance,as well as brain-computer-interface,etc.Fork-like 32-site microelectrodes are developed with silicon.By use of integrated circuit technology,the length of the electrodes,the area of the recording sites,as well as the spaces between the sites are closely controlled.SiO2/SiNx/SiO2composite dielectric membrane and Pt black are introduced to improve the characteristics of the electrodes.The whole thickness of the thin-film probe was 21μm.By combining the modifying process with the micro-fabrication method,this kind of silicon based microelectrode satisfies high-density recording and the performance characterization is evaluated by test in vitro and in vivo.CHEN SanYuan PEI WeiHua ZHAO Hui GUI Qiang TANG RongYu CHEN YuanFang FANG XiaoLei HONG Bo GAO XiaoRong CHEN HongDa 2014Science China(Information Sciences)2014,57,5:2
6Specific biotests to assess eco-toxicity of biodegradable polymer materials in soil显示文摘Eco-toxicity investigation of polymer materials was considered extremely necessary for their potential menace,which was widely use as mulching materials in agricultural.In this study,polyethylene(PE),polystyrene(PS)and synthetic biomaterials-Ecoflex and cellulose were applying into soil cultivated with two potential indicator plants species:oat(A v ena sati v a)and red radish(Raphanus sativum).Variety of chemical,biochemical parameters and enzyme activity in soil were proved as effective approach to evaluate polymers phytotoxicity in plant-soil mesocosm.The F-value of biomass,pH,heavy metal and electoral conductivity of Raphanus behaved significant different from T0.Significant analysis results indicated biodegradation was fast in PE than PS,besides,heavy metals were dramatically decrease in the end implied the plant absorption may help decrease heavy metal toxicity.The increase value at T2 of Dehydrogenase activity(0.84 higher than average value for Avena&0.91 higher for Raphanus),Metabolic Index(3.12 higher than average value for Avena&3.81 higher for Raphanus)means during soil enzyme activity was promoted by biodegradation for its heterotrophic organisms’energy transportation was stimulated.Statistics analysis was carried on Biplot PC1(24.2%of the total variance),PC2(23.2%of the total variance),versus PC3(22.8%of the total variance),which indicated phosphatase activity and metabolic index was significant correlated,and high correlation of ammonium and protease activity.Furthermore,the effects were more evident in Raphanus treatments than in Avena,suggesting the higher sensitivity of Raphanus to polymers treatment,which indicate biodegradation of polymers in Raphanus treatment has produced intermediate phytotoxic compounds.Haiyan Chen Fei Wang Huilun Chen HongDa Fang Weiying Feng Yuan Wei FanFan Wang HaiLei Su YiDong Mi Min Zhou XinRu Li Serena Doni Andrea Corti 2021Journal of Environmental Sciences2021,33,7:2
7Characterization of the chemical fungicides-responsive and bacterial pathogen-preventing Bacillus licheniformis in rice spikelet显示文摘Seed-borne bacterial pathogens cause severe yield loss and biotoxin contamination in rice,leading to increasing concern on the global food supply and environmental safety.Plant native microbes play an important role in defending against diseases,but their actions are often influ-enced by the chemical fungicides applied in the field.Here,Bacillus licheniformis mmj was isolated from rice spikelet,which uniquely showed not only fungicide-responsiveness but also broad-spectrum antimicrobial activity against major rice bacterial pathogens including Xanthomonas oryzae pv.oryzae,Burkholderia plantari and Burkholderia glumae.To understand the hallmark underlying the environmental adaptation and anti-microbial activity of B.licheniformis mmj,the genome sequence was determined by SMRT and subjected to bioinformatics analysis.Genome sequence analysis enabled the identification of a set of antimicrobial-resistance and antibacterial activity genes together with an array of harsh environment-adaptive genes.Moreover,B.licheniformis mmj metabolites were analyzed with gas chromatography coupled to triple quadrupole mass spectrometry,and the volatile components that were linked with the antimicrobial activity were preliminarily profiled.Collectively,the present findings reveal the genomic and metabolic landscapes underlying fungicide-responsive B.licheniformis,which offers a new opportunity to design harsh environment-adaptive biopesticides to cope with prevalent bacterial phytopathogens.Chengfang Zhan Mengchen Wu Hongda Fang Xiaoyu Liu Jiuyue Pan Xiaoyan Fan Mengcen Wang Haruna Matsumoto 2023Food Quality and Safety2023,7,2:1
8A 16-channel high-voltage reconfigurable and flexible-controlled implantable wireless closed-loop system for SCI repair显示文摘An adaptive closed-loop system for spinal cord injury(SCI) repair is designed. It integrates stimulation and recording on 16 pairs of electrodes. Two switches(SAS3 T16/SAS1 T16 X2) fabricated in high-voltage 0.8 μm process with online re-configurable function are proposed. These two switches are combined with commercial off-the-shelf(COTS) electronics to implement the closed-loop implantable system in compact module. The system includes amplifier for recording neural signals, high-voltage stimulator, power transmission device, central processing module and flexible implantable electrodes. Two customized switches route any electrode to amplifier or stimulator, and nerve stimulation and signal recording are performed through lead wire-driven channels. The entire system is able to operate at up to 28 V, and is a biocompatible package with a volume of 42 mm×35 mm×8 mm. This system solves several problems encountered in implantable devices: low flexibility, negative influence of stimulus artifacts on neural detection and low integration of electrodes.闫寒冰 Zhang Xu Liu Ming Yuan Fang Wang Sikai Chen Hongda 2020High Technology Letters2020,26,1:0
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费