|
|
|
题名
|
作者
|
年代
|
出处
|
被引量
|
| 1 | Comparison of corneal endothelial changes following phacoemulsification with transversal and torsional phacoemulsification machines显示文摘AIM:To compare and evaluate the phacoemulsification parameters and postoperative endothelial cell changes of two different phacoemulsification machines, each with different modes, but also to assess the relationship between postoperative endothelial cell loss and the phacoemulsification parameters, as well as the other factors in both groups.METHODS:This prospective observational study was comprised of consecutive eligible cataract patients operated with phacoemulsification technique performed by the same surgeon using either a WHITESTAR Signature Ellips FX(transversal, group 1) or Infiniti OZil IP(torsional, group 2) machine.RESULTS:The study included 86 patients. Baseline characteristics in the groups were similar. The median nuclear sclerosis grade was 3(2-4) in the first group and2(2-4) in the second group(P =0.265). Both groups had similar phacoemulsification needle times(group 1: 60.63±36 s; group 2: 55.98±30 s; P =0.789). The percentage of endothelial cell loss 30 d after surgery ranged from 3% to15% with a median of 7% in group 1, and from 2% to13% with a median of 6% in group 2; however, there was no statistically significant difference between the groups(P =0.407). Hexagonality(P =0.794) and the coefficient of variation(CV; P =0.142) did not differ significantly between the groups before and 30 d after surgery. Asignificant positive correlation was found between the endothelial cell loss and nuclear sclerosis grade(group1: P <0.001; group 2: P <0.001) and between the endothelial cell loss and average phacoemulsification power(group 1: P =0.007; group 2: P =0.008).CONCLUSION:Both of these machines were efficient,with similar endothelial cell loss. This endothelial cell loss was related to the increased nuclear sclerosis grade and increased phacoemulsification power. | Mustafa Atas Süleyman Demircan Arzu Seyhan Karatepe Hashas Ahmet Gülhan Gkmen Zararsιz | 2014 | International Journal of Ophthalmology(English edition)2014,7,5: | 7 |
| 2 | Evaluation of early results of quick-chop phacoemulsification in the patients with high myopic cataract显示文摘AIM:To assess the early surgical outcomes of quickchop phacoemulsification technique in patients with high myopia.METHODS:The data of patients with high myopia who underwent quick-chop phacoemulsification were reviewed retrospectively. There were 42 eyes of 31 patients. The axial length was more than 26 mm in all eyes. All eyes underwent quick-chop phacoemulsification surgery with the placement of an intraocular lens(IOL) in the capsular bag. Postoperative visits were performed at 1, 3d; 2wk,1mo. Early postoperative best corrected visual acuity(BCVA), preoperative and postoperative corneal endothelial cell density(ECD), central corneal thickness(CCT) and postoperative complications were assessed.Paired sample t-test or Wilcoxon tests were used to compare data between preoperative and postoperative data.· RESULTS:There was no statistically significant difference between preoperative and postoperative ECD and CCT. Retinal detachment was developed in one eye at postoperative first day. There was an iris prolapsus from side port insicion.· CONCLUSION:Quick-chop phacoemulsification technique is a safe surgical technique. However we can encounter some complications in high myopic eyes due to histopathological differences. Both side port and clear corneal tunnel insicion size is crucial for preventing postoperative complications. If any persistent leakage is noticed, suture should be placed. | Ali Akal Tugba Goncu Sevin Soker Cakmak Isa Yuvaci Mustafa Atas Süleyman Demircan Omer Faruk Yilmaz | 2014 | International Journal of Ophthalmology(English edition)2014,7,5: | 4 |
| 3 | Comparison of 45- degree Kelman and 45- degree balanced phaco tip designs in torsional microcoaxial phacoemulsification显示文摘AIM: To compare the intraoperative performance and postoperative outcome after microcoaxial torsional phacoemulsification using either a Kelman or balanced phaco tip.· METHODS: Cataracts were treated using 2.2 mm microcoaxial torsional phacoemulsification using either a45-degree mini-flared Kelman or a 45-degree IntrepidBalanced phaco tip. Intraoperative measurements included total ultrasound(US) time, cumulative dissipated energy(CDE), torsional US time, and balanced salt solution(BSS) use. The central endothelial cell density(ECD) and central corneal thickness(CCT) were evaluated preoperatively and postoperatively 1, 7, and30 d after surgery using noncontact specular microscopy.·RESULTS: The 116 enrolled eyes(116 patients) were divided equally between the Kelman and balanced tip groups. Intraoperative measurements showed significantly less total US time, torsional US time, CDE, and BSS use in the balanced group than in Kelman group(P <0.05).The total US time, torsional US time, CDE, and BSS use were 17.45 ±14.53 s, 16.63 ±13.97 s, 6.38 ±5.26, and 48.21 ±17.21 m L in the Kelman group and 11.39 ±9.60 s, 10.90 ±9.25 s, 4.04 ±3.42, and 41.36 ±12.70 m L in the balanced group, respectively.·CONCLUSION: Torsional phacoemulsification performed with a balanced tip provided more effective lens removal with less total US time, torsional time, CDE, and BSS use, as well as similar changes in ECD with a Kelman tip in all cataract grades. This special designed phaco tip for torsional phacoemulsification provides an alternative phaco tip for many surgeons' preference with straight phaco tip. | Süleyman Demircan Mustafa Atas Emre Goktas Burhan Baskan | 2015 | International Journal of Ophthalmology(English edition)2015,8,6: | 3 |
| 4 | Effect of torsional mode phacoemulsification on cornea in eyes with/without pseudoexfoliation显示文摘AIM: To evaluate the effect of torsional mode phacoemulsification on central corneal thickness, corneal endothelial cell density, and morphology in eyes with/without pseudoexfoliation(PEX) syndrome.METHODS: Fourty-two consecutive patients with and42 patients without PEX as a control group scheduled for cataract surgery was studied. Phacoemulsification, using OZi L IP system, was performed with quick chop technique. Using noncontact specular microscopy, the central endothelial cell density(ECD), coefficient of variation, percentage of hexagonal cells, and the central corneal thickness(CCT) were evaluated preoperatively and postoperatively at 1, 7 and 30 d.RESULTS: The ECD in PEX syndrome was statistically significantly lower than that in the control group preoperatively and postoperatively(P ≤0.001).Percentage change in ECD was statistically significantly higher in PEX than that in control group after surgery follow up(P ≤0.04).There was no statistically significant difference between both groups comparing percentage of hexagonal cells and coefficient of variation in the cell size before and after the surgery. At 1 and 7d after surgery, percentage change in CCT was statistically significantly higher in PEX group than that in the control group(P ≤0.041).CONCLUSION: Although torsional mode phacoemulsification and intraocular lens(IOL) implantation provided a safe and favorable surgical outcome in patients with/without PEX, torsional phacoemulsification led to significantly higher ECD loss in the PEX group than that in the control group during the whole follow up period.In addition, more corneal swelling in the PEX group than that in the control group during the early postoperative period has indicated that the corneal endothelium, in presence of PEX endotheliopathy, seems to be more susceptible to the effects of phacoemulsification surgeryin eyes with PEX. The increased risk of anterior chamber manipulations in patients with PEX should be taken into account for an increased risk of bullous keratopathy. | Süleyman Demircan Mustafa Atas Yusufcan Yurtsever | 2015 | International Journal of Ophthalmology(English edition)2015,8,2: | 3 |
| 5 | Multi-product production quantity model with repair failure and partial backordering显示文摘 | ATA A T WEE H M SEYED J S | 2010 | Computers and Industrial Engineering2010,59,1: | 1 |
| 6 | Effects of moxifloxacin exposure on the conjunctival flora and antibiotic resistance profile following repeated intravitreal injections显示文摘AIM:To evaluate the effects of moxifloxacin exposure on the conjunctival flora and antibiotic resistance profile following repeated intravitreal injections.METHODS:Seventy-two eyes of 36 patients [36 eyes in control group, 36 eyes in intravitreal injection(IVI) group]were enrolled in the study. All the eyes had at least one IVI and had diabetic macular edema(DME) or age-related macular degeneration(ARMD). Moxifloxacin was prescribed to all the patients four times a day for five days following injection. Conjunctival cultures were obtained from the lower fornix via standardized technique with every possible effort made to minimize contamination from the lids, lashes, or skin. Before the application of any ophthalmic medication, conjunctival cultures were obtained from both eyes using sterile cotton culture. An automated microbiology system was used to identify the growing bacteria and determine antibiotic sensitivity.RESULTS:The bacterial cultures were isolated from 72 eyes of 36 patients, sixteen of whom patients(44.4%)were male and twenty(55.6%) were female. Average age was 68.4 ±9.0(range 50-86). The average number of injections before taking cultures was 3.1+1.0. Forty-eight(66.7%) of 72 eyes had at least one significant organism.There was no bacterial growth in 8(20.5%) of IVI eyes and in 16(44.4%) of control eyes(P =0.03). Of the bacteria isolated from culture, 53.8% of coagulase negative staphylococci(CoNS) in IVI eyes and 47.2%CoNS in control eyes. This difference between IVI eyes and control eyes about bacteria isolated from culture was not statistically significant(P =0.2). Eleven of 25 bacteria(44.0%) isolated from IVI eyes and 11(57.9%) of 19 bacteria isolated from control eyes were resistant to oxacillin. The difference in frequency of moxifloxacine resistance between two groups was not statistically significant(12.0% in IVI eyes and 21.1% in control eyes)(P =0.44). There were no cases of resistance to vancomycin, teicoplanin and linezolid.CONCLUSION:There was no difference in species of bacteria isolated from cultures, or in the frequency of resistance to antibiotics between eyes that had recurrent IVI followed by moxifloxacin exposure compared with control eyes. However, the number of eyes that had bacterial growth was higher in IVI group than in the control group. | Mustafa Atas Burhan Baskan Ayse zkse Fatma Mutlu Sarιgüzel Süleyman Demircan Emine Pangal | 2014 | International Journal of Ophthalmology(English edition)2014,7,5: | 1 |
| 7 | Determination of low level nitrite and nitrate in biological, food and environmental samples by gas chromatography-mass spectrometry and liquid chromatography with fluorescence detection显示文摘 | Akyuz M Ata S | 2009 | Talanta2009,79,3: | 1 |
| 8 | High dose eabergolinein management of ovarian hyperstimulation syndrome 显示文摘 | Ata B Seyhan A Orhaner S | 2009 | Fertil Steril2009,5,: | 1 |
| 9 | Simultaneous determination of aliphatic and aromatic amines in water and sediment samples by ion-pair extraction and gas chromatography-mass spectrometry显示文摘 | Akyuz M Ata S | 2006 | Journal of Chromatography A2006,1129,1: | 1 |
| 10 | Preparation andimmuno('hemit*al characterization ofantihody to branched I)-gluoan of Volvariella volvacea,and its use in studies of antitumoractions显示文摘 | Kishida E Sone Y Shil)ata S | 1989 | Agric Hiol Chem1989,53,7: | 1 |
| 11 | Imaging of ungrouted tendon ducts in prestressed concrete by improved SIBIE显示文摘 | Ata N Mihara S Ohtsu M | 2007 | NDT&E International2007,40,: | 1 |
| 12 | Effect of polychlorinated biphenyls(PCBs)and 1,1,1-trichloro-2,2,-bis(4-chlorophenyl)-ethane(DDT)in follicular fluid on the results of in vitro fertilization-embryo transfer(IVFET)programs显示文摘 | JirsováS Maata J Jech L | 2010 | Fertility and Sterility2010,93,6: | 1 |
| 13 | Revised American thyroid association management guidelines for patients with thyroid nodules and differentiated thyroid Cancer显示文摘 | American Thyroid Association (ATA) Guidelines Taskforce on Thyroid Nodules and Differentiated Thyroid Cancer Cooper D S Doherty G M | 2009 | Thyroid2009,19,11: | 1 |
| 14 | Sodium-glucose co-transporter 2 inhibitors induced euglycemic diabetic ketoacidosis within four days of initiation显示文摘Euglycemic diabetic ketoacidosis(EDKA)is a well-known complication of sodium-glucose co-transporter 2 inhibitors,and many cases with variable onset following the initiation of these agents are reported before,with a median onset of approximately 2 wk.This letter discusses a 45-year-old lady who initially presented with ischemic stroke but developed EDKA 4 d after starting empagliflozin,a rare occurrence.The patient had severe metabolic acidosis that necessitated admission into the intensive care unit.Prompt discontinuation of empagliflozin and DKA management resulted in clinical recovery. | Almurtada Razok Fateen Ata Sara Mohamed Ibrahim Ahmed Dabia Hamad S H Al Mohanadi | 2022 | World Journal of Diabetes2022,13,3: | 1 |
| 15 | Phenomena in the froth phase of flotation:A review显示文摘 | Ata S | 2012 | International Journal of Minerals Processing2012,102,10: | 1 |
| 16 | Volatile constituents of cooked bullfrog (Rana catesbeiana) legs显示文摘 | N6BREGA I C C ATA MOURA O M | 2007 | Food Chemistry2007,102,1: | 1 |
| 17 | The effect of hydrophobicity on the drainage of gangue minerals in flotation froths 显示文摘 | Ata S Ahmed N Jameson G J | 2004 | Minerals Engineering2004,17,: | 1 |
| 18 | IPv6 Anycast for simple and effective communications 显示文摘 | Doi S Ata S Kitamura H | 2004 | IEEE Communications Magazine2004,42,5: | 1 |
| 19 | Imaging of ungrouted tendon ducts in prestressed concrete by improved SIBIE显示文摘 | Ata N Mihara S Ohtsu M | 2007 | NDT & E International2007,40,3: | 1 |
| 20 | Capillary forces between surfaces with nanoscale roughness显示文摘 | Yakov I Rabinovich Joshua J Adler Madhavan S Esayanur Ali Ata Rajiv K Singh Brij M Moudgil | 2002 | Advances in Colloid and Interface Science2002,,1: | 1 |