维普中文期刊产品整合服务
共被期刊论文引用了2次 您的检索式:您选中1篇文献正在查看引证文献汇总
    题名 作者 年代 出处 被引量
1Autogenous inside-out versus standard vein and skeletal muscle-combined grafting for facial nerve repair显示文摘BACKGROUND:In the repair of nerve defects,collapse of the venous wall,as a result of vein grafting alone,could impede nerve regeneration.Therefore,vein lumens filled with muscle and nerve segments have been used to bridge nerve defects.OBJECTIVE:To compare the effects of autogenous,inside-out,vein-skeletal,muscle-combined grafting versus standard,vein-skeletal,muscle-combined grafting for the repair of facial nerve defects.DESIGN,TIME AND SETTING:A randomized,controlled,neuroanatomical,animal study was performed at the Animal Experimental Center and Laboratories of the Capital Medical University Xuanwu Hospital and the Peking Union Medical College Hospital from September 2007 to October 2008.MATERIALS:A total of 10 healthy,male,New Zealand rabbits,aged 6 months,were randomly assigned to inside-out,vein-skeletal,muscle-combined grafting and standard,vein-skeletal,muscle-combined grafting groups,with 5 rabbits in each group.METHODS:A 20-mm gap in the buccal branch of the right facial nerve was made in each animal,which was respectively repaired with inside-out,vein-skeletal,muscle-combined grafts or standard vein-skeletal muscle-combined grafts.MAIN OUTCOME MEASURES:At 6 months after implantation,evoked maximal compound muscle action potentials were recorded on bilateral facial nerves using electromyogram.Myelinated nerve fibers of the regenerating nerves were quantified using myelin sheath osmic acid staining.RESULTS:There was no significant difference between the groups in terms of ratios of bilateral amplitude and latency of compound muscle action potential(P>0.05).Moreover,morphology of regenerating nerves and quantity of myelinated nerve fibers were similar between the groups(P> 0.05).CONCLUTION:Compared with standard vein grafting,the inside-out vein grafting did not significantly improve nerve regeneration.Therefore,it is not necessary to utilize inside-out vein grafting for the repair of nerve defects,in particular with the combined use of autogenous vein and skeletal muscle grafts.Yulu Li Zhiqiang Gao Zhenlin Wang Yonggang Liu Qiuhang Zhang 2010Neural Regeneration Research2010,5,4:5
2Fascial pedicle artificial nerve tissue compared with silicone tube bridging to repair sciatic nerve defects in rats显示文摘BACKGROUND: Silicone tube bridging for peripheral nerve defects has been shown to be successful in guiding neural regeneration.However,this method is accompanied by complications.Because materials for bridging nerve fibers should exhibit biocompatibility,the development of novel artificial tissues to bridge nerve grafts has become important in the field of nerve tissue engineering for the repair of peripheral nerve defects.OBJECTIVE: To investigate effectiveness and feasibility of fascial pedicle artificial nerve tissue to repair peripheral nerve defects,and to compare to autologous nerve grafts and silicone tube bridging methods.DESIGN,TIME,AND SETTING: Randomized,controlled,neural tissue engineering-based,animal experiments were performed at the Laboratory of Human Anatomy in Qingdao University Medical College from March 2006 to March 2007.MATERIALS: Medical absorbable collagen sponge was purchased from Henan Province Tiangong Bio-Material,China.Cantata 2-track 4-trace EMG-evoked potential instrument was purchased from Dantec,Denmark.Medical silicone tube was purchased from Shenzhen Legend Technology,China.METHODS: Forty healthy,adult,male,Sprague Dawley rats were randomly assigned to four groups: fascial pedicle nerve,autologous nerve,silicone tube,and normal,with 10 rats in each group.A 10-mm defective sciatic nerve section was produced in rats following the removal of the fascial pedicle.The fascial flap surrounding the defect was harvested;one side of the nerve pedicle was maintained and then sutured into a tube with the fascia surface as the pipe inner wall.The tube was filled with a medical absorbable collagen (Bodyin) to construct a bridge between the artificial tissue nerve graft and the damaged sciatic nerve.The sciatic nerve defects in the autologous nerve and silicone tube groups were bridged using autologous nerve grafts and a medical silicone tube with matched specifications.MAIN OUTCOME MEASURES: At 4 months after transplantation,electromyogram was used to detect sciatic nerve conduction velocity and action potential amplitude.Hematoxylin-eosin and Nissl staining were used to determine the number of spinal cord anterior horn motor neurons and neurites.Osmium tetroxide staining of the sciatic nerve bridge section was performed to detect the number and diameter of nerve fibers.RESULTS: There were no differences in sciatic nerve conduction velocity,action potential amplitude,the number of spinal cord anterior horn motor neurons and neurites,sciatic nerve fiber number,and diameter between the autologous nerve graft and normal groups (P > 0.05).However,these values were significantly greater than in the silicone tube group (P < 0.05).CONCLUSION: Quantitative results suggested that artificial nerve tissue,with an autologous tissue fascia flap as a nerve conduit,could be used to repair peripheral nerve defects.The regenerated fascial pedicle artificial nerve tissue was similar to an autologous nerve graft in terms of morphology and functional recovery and was superior to results from silicone tube bridging transplants.Xu He Xiaofei Wang Jing Zhao Wenhua Li Yuanxin Zhang Zhigang Qu Guanghai Yuan Huanfang Chi 2010Neural Regeneration Research2010,5,5:0
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费