维普中文期刊产品整合服务
2篇 您的检索式:作者名="Zechen Lin"
    题名 作者 年代 出处 被引量
1The DELLA-ABI4-HY5 module integrates light and gibberellin signals to regulate hypocotyl elongation显示文摘Plant growth is coordinately controlled by various environmental and hormonal signals,of which light and gibberellin(GA)signals are two critical factors with opposite effects on hypocotyl elongation.Although interactions between the light and GA signaling pathways have been studied extensively,the detailed regulatory mechanism of their direct crosstalk in hypocotyl elongation remains to be fully clarified.Previously,we reported that ABA INSENSITIVE 4(ABI4)controls hypocotyl elongation through its regulation of cellelongation-related genes,but whether it is also involved in GA signaling to promote hypocotyl elongation is unknown.In this study,we showthat promotion of hypocotyl elongation by GA is dependent on ABI4 activation.DELLAs interact directly with ABI4 and inhibit its DNA-binding activity.In turn,ABI4 combined with ELONGATED HYPOCOTYL 5(HY5),a key positive factor in light signaling,feedback regulates the expression of the GA2ox GA catabolism genes and thus modulates GA levels.Taken together,our results suggest that the DELLA-ABI4-HY5 module may serve as a molecular link that integrates GA and light signals to control hypocotyl elongation.Haibo Xiong Dandan Lu Zhiyuan Li Jianghao Wu Xin Ning Weijun Lin Zechen Bai Canhui Zheng Yang Sun Wei Chi Lixin Zhang Xiumei Xu 2023Plant Communications2023,4,5:0
2Analysis of Gas Flow Rate and Pressure Loss of Medical Mask Differential Pressure Tester显示文摘The objective of this study is to find a suitable method to overcome the pressure loss problem in the gas pipe during the gas exchange detection of medical masks.Based on the European Standards EN 14683,the parameters of a medical mask differential pressure tester were selected,subsequently two schemes of gas pipe layouts were designed,including four kinds of pipe diameter which are 4,5,6.5,and 8mm respectively.Lastly,the models of each scheme were established and imported into Fluent,and the relevant parameters were set for simulation.After data analysis,the results showed that among the four different pipe diameters,the pressure loss of 8mm diameter of the pipe was lower in both the schemes,additionally the pressure loss of the second scheme(the gas pipe was short and smooth)was lower under the same pipe diameter.At the flow rate of v=8L/min,the pressure loss from the inlet to the measurement point is less than 200Pa,and the estimated measurement error is less than 1.5%.In conclusion,shortening the length of the pipe,and increasing the diameter of the pipe can reduce the gas pressure loss,subsequently improve the measurement accuracy of the medical mask differential pressure tester.Zechen Lin Qing Zhang Jianjun Sun Xiujun Yao 2022Journal of Clinical and Nursing Research2022,6,4:0
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费