维普中文期刊产品整合服务
1篇 您的检索式:作者名="Rachel Hackett"
    题名 作者 年代 出处 被引量
1A prospective trial of volumetric intensity-modulated arc therapy vs conventional intensity modulated radiation therapy in advanced head and neck cancer显示文摘AIM: To prospectively compare volumetric intensitymodulated arc therapy(VMAT) and conventional intensity-modulated radiation therapy(IMRT) in coverage of planning target volumes and avoidance of multiple organs at risk(OARs) in patients undergoing definitive chemoradiotherapy for advanced(stage Ⅲ or Ⅳ)squamous cell cancer of the head and neck. METHODS: Computed tomography scans of 20 patients with advanced tumors of the larynx, naso-, oroand hypopharynx were prospectively planned using IMRT(7 field) and VMAT using two arcs. Calculated doses to planning target volume(PTV) and OAR were compared between IMRT and VMAT plans. Dose-volume histograms(DVH) were utilized to obtain calculated doses to PTV and OAR, including parotids, cochlea,spinal cord, brainstem, anterior tongue, pituitary and brachial plexus. DVH's for all structures were compared between IMRT and VMAT plans. In addition the planswere compared for dose conformity and homogeneity. The final treatment plan was chosen by the treating radiation oncologist. RESULTS: VMAT was chosen as the ultimate plan in 18 of 20 patients(90%) because the plans were thought to be otherwise clinically equivalent. The IMRT plan was chosen in 2 of 20 patients because the VMAT plan produced concentric irradiation of the cord which was not overcome even with an avoidance structure. For all patients, VMAT plans had a lower number of average monitor units on average(MU = 542.85) than IMRT plans(MU = 1612.58)(P < 0.001). Using the conformity index(CI), defined as the 95% isodose volume divided by the PTV, the IMRT plan was more conformal with a lower conformity index(CI = 1.61) than the VMAT plan(CI = 2.00)(P = 0.003). Dose homogeneity, as measured by average standard deviation of dose distribution over the PTV, was not different with VMAT(1.45 Gy) or IMRT(1.73 Gy)(P = 0.069). There were no differences in sparing organs at risk.CONCLUSION: In this prospective study, VMAT plans were chosen over IMRT 90% of the time. Compared to IMRT, VMAT plans used only one third of the MUs, had shorter treatment times, and similar sparing of OAR. Overall, VMAT provided similar dose homogeneity but less conformity in PTV irradiation compared to IMRT. This difference in conformity was not clinically significant.Simon D Fung-Kee-Fung Rachel Hackett Lee Hales Graham Warren Anurag K Singh 2012World Journal of Clinical Oncology2012,3,4:2
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费