维普中文期刊产品整合服务
5篇 您的检索式:作者名="PROBAL CHAUDHURI"
    题名 作者 年代 出处 被引量
1Thresholding in Edge Detection : A Statistical Approach 显示文摘RISHI R RAKESH PROBAL CHAUDHURI MURTHY C A 2004IEEE Trans Image Processing2004,13,7:1
2Design and development of a plastic scintillator based whole body β/γ contamination monitoring system显示文摘Plastic scintillation detectors based whole body β/γ contamination monitors are developed for use in radiation facilities.This microcontroller-based multi-detector system uses 13 plastic scintillator detectors,with minimized dead detection zones,monitoring the whole body,and conforming to the contamination limit prescribed by the regulatory authority.This system has the features for monitoring hands,feet,head,and faceβ/γusing contamination monitors and portal exit monitors.It can detect gamma sources at a dose rate of 10 n Gyh^(-1).The system is calibrated using b sources^(90)Sr/^(90)Y,^(204)Tl,and^(36)Cl,and the efficiency is found to be 29%,22%,and 18%,respectively.Theminimumdetectableβ/γcontaminationis0.15 Bqcm^(-2),which is significantly less than the minimum detection objectives on head,face,hands,and feet.Vaishali M.Thakur Amit Jain P.Ashokkumar Rekha Anilkumar Pravin Sawant Probal Chaudhury L.M.Chaudhari 2021Nuclear Science and Techniques2021,32,5:1
3Statistical Significance Of Features In Digital Images显示文摘F Godtliebsen J S Marron Probal Chaudhuri 2004Image and Vision Computing2004,,22:1
4A statistical approach显示文摘Rishi R Rakesh Probal Chaudhuri Murthy C A 2004IEEE Transactions on Image Processing2004,13,7:1
5Plastic scintillator detector for qualitative and quantitative measurements of gamma radiation显示文摘Background Plastic scintillator detectors are rugged and easily manufactured in desired shape,sizes and response time to gamma radiation is prompt as compared with any other scintillator detectors.Being popular these detectors are used in radiation monitors one of the application to restrict radioactive material movement.These are used in gross counting mode to know the presence of radioactivity.Therefore secondary survey is required to know the nature of the radionuclides.Purpose The feasibility study of Cylindrical Plastic Scintillator Detector(CPSD)was carried out for the qualitative and quantitative assessment of gamma emitting radionuclides.Methods In this work limited gamma spectrometry was carried out using NE110 equivalent cylindrical plastic scintillating material of 5.1 cm diameter and 100 cm long.CPSD is optically coupled to photomultiplier tube(PMT).The detector signal is processed using preamplifier,shaping amplifier and further analysed by a multi channel analyser(MCA).CPSD gamma spectrum consists of Compton continuum and Gaussian shaped Compton edge energy(λ_(e))appearing as Compton maxima energy(λ_(max)).Photon transport simulation is used to characterizeλ_(max) as a signature for radionuclides emitting gamma energy/energies.In case of unresolved gamma energies,it appears as weighted effective Compton maxima energy.The prominent gamma energies observed across nuclear industries are in the energy range 0.03–3 MeV.It is grouped as low energy,intermediate energy,high energy and ultra-high energy window.The simulated spectrum is obtained suing Gaussian broadening parameters deduced from experimentally measured spectrum.The efficiency response function is developed from simulated response of detector to standard gamma sources under known source detector configurations.Results The mono energetic gamma emitting radioisotopes are identified againstλ_(max) from data library.Qualitative analysis of spectrum is used to discriminate artificial radioactive material from naturally occurring radioactive material using gamma photon,corresponding Compton edge and expected Compton maxima in each energy window.The provisional quantitative assessment is carried out using efficiency deduced from response function.The detection efficiency varies within 1%–0.2%for 0.03 to 3 MeV gamma energies.In this study efficiency for ^(137)Cs source is 0.26%with FWHM 0.092 MeV and the results re within 15%for the measured activity.Estimated sensitivity and spectral dose rate coefficient for CPSD are 77 cps/µR/h and 44.29 nGy/kcps respectively.The MDA or MDL of the most prominent radioisotopes used in nuclear industry are estimated.CPSD showed an ability to detect 149 kBq,^(137)Cs radioisotope at 1 m distance.Conclusion CPSD can be utilised for gamma isotope identification with limited gamma spectroscopy tool in contamination and dose rate measurements monitors.Vaishali M.Thakur Nitin Bhosale Amit Jain Mukesh Sharma L.M.Chaudhari Probal Chaudhury 2023Radiation Detection Technology and Methods2023,7,4:0
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费