维普中文期刊产品整合服务
3篇 您的检索式:作者名="Muftuler L"
    题名 作者 年代 出处 被引量
1Contrast and spatial resolution in MREIT using low amplitude cur- rent 显示文摘Birgul O Hamamura M Muftuler L 2006Physics in Medicine and Biology2006,51,19:1
2FMRI study relevant to the Mozart effect:Brain areas involved in spatial-temporal reasoning显示文摘BODNER M MUFTULER L T NALCIOGLU O 0,,07:1
3Cardiac functional magnetic resonance imaging at 7T:Image quality optimization and ultra-high field capabilities显示文摘BACKGROUND 7T cardiac magnetic resonance imaging(MRI)introduces several advantages,as well as some limitations,compared to lower-field imaging.The capabilities of ultra-high field(UHF)MRI have not been fully exploited in cardiac functional imaging.AIM To optimize 7T cardiac MRI functional imaging without the need for conducting B1 shimming or subject-specific tuning,which improves scan efficiency.In this study,we provide results from phantom and in vivo scans using a multi-channel transceiver modular coil.METHODS We investigated the effects of adding a dielectric pad at different locations next to the imaged region of interest on improving image quality in subjects with different body habitus.We also investigated the effects of adjusting the imaging flip angle in cine and tagging sequences on improving image quality,B1 field homogeneity,signal-to-noise ratio(SNR),blood-myocardium contrast-to-noise ratio(CNR),and tagging persistence throughout the cardiac cycle.RESULTS The results showed the capability of achieving improved image quality with high spatial resolution(0.75 mm×0.75 mm×2 mm),high temporal resolution(20 ms),and increased tagging persistence(for up to 1200 ms cardiac cycle duration)at 7T cardiac MRI after adjusting scan set-up and imaging parameters.Adjusting the imaging flip angle was essential for achieving optimal SNR and myocardium-toblood CNR.Placing a dielectric pad at the anterior left position of the chest resulted in improved B1 homogeneity compared to other positions,especially in subjects with small chest size.CONCLUSION Improved regional and global cardiac functional imaging can be achieved at 7T MRI through simple scan set-up adjustment and imaging parameter optimization,which would allow for more streamlined and efficient UHF cardiac MRI.El-Sayed H Ibrahim V Emre Arpinar L Tugan Muftuler Jadranka Stojanovska Andrew S Nencka Kevin M Koch 2020World Journal of Radiology2020,12,10:0
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费