维普中文期刊产品整合服务
1篇 您的检索式:作者名="Hasit Joshi"
    题名 作者 年代 出处 被引量
1Response of blood pressure after percutaneous transluminal renal artery angioplasty and stenting显示文摘AIM: To evaluate the short and intermediate term out-come of percutaneous transluminal renal artery angioplasty (PTRA) and stenting particularly on blood pressure (BP) control and renal function and to evaluate predictors of poor BP response after successful PTRA and stenting. METHODS: We conducted a prospective analysis of all patients who underwent PTRA and stenting in our institute between August 2010 to September 2012. A total number of 86 patients were underwent PTRA and renal stenting. Selective angiography was done to confirm at least 70% angiographic stenosis. The predilatation done except few cases with critical stenosis, direct stenting was done in the rest of cases. All patients received aspirin 325 mg orally, and clopidogrel 300 mg orally within 24 h before the procedure. Heparin was used as the procedural anticoagulant agent. Optimal results with TIMI-Ⅲ flow obtained in all cases. Following stent placement, aspirin 150 mg orally once daily was continued for a minimum of 12 mo and clopidogrel 75 mg orally once daily for at least 4 wk. The clinical, radiological, electrocardiography, echocardiography and treatment data of all patients were recorded. The BP measurement, serum creatinine and glomerular filtration rate (GFR) were recorded before the procedure and 1 and 6 mo after PTRA. RESULTS: A total of 86 patients were included in the study. The mean age of study population was 55.87±11.85 years old and 67 (77.9%) of patients were male. There was a significant reduction in both systolic and diastolic BP at 1 mo after the procedure: 170.15±20.10 mmHg vs 146.60±17.32 mmHg and 98.38±10.55 mmHg vs 89.88±9.22 mmHg respectively (P=0.0000). The reduction in BP was constant throughout the follow-up period and was evident 6 mo after the procedure: 144.23±18.19 and 88.26±9.79 mmHg respectively (P=0.0000). However, no improvement in renal function was observed at any time during the follow-up period. After multivariate analysis, we found male sex, low GFR (<60 mL/min) and higher baseline mean BP as a poor predictors of successful outcome on BP response after PTRA and stenting. CONCLUSION: The PTRA and stenting can be considered as an effective therapeutic intervention for improving BP control with minimal effect on renal function. The male sex, higher baseline BP and low GFR are associated with poor BP response after successful PTRA and stenting.Jayesh S Prajapati Sharad R Jain Hasit Joshi Shaurin Shah Kamal Sharma Sibasis Sahoo Kapil Virparia Ashok Thakkar 2013World Journal of Cardiology2013,5,7:3
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费