| 1 | Crystal structure determining of 7-ADCA based on X-ray powder diffraction显示文摘Optimum resolution data of X-ray pow- der diffraction for 7-amino desacetoxy cephalospo- ranic acid(7-ADCA) were collected from an X′ Pert Pro MPD diffractometer with the setup of 0.01°/s and 0.01° per step. Indexing to the crystal system and searching space group from the diffraction data were conducted by means of the computational crystal- lography method. The pilot crystal models of 7-ADCA were then refined by Rietveld method to obtain the exact three-dimensional structure. The results show that the crystal structure of 7-ADCA is monoclinic, space group P21 with unit cell dimensions a=13.50 ?, b=6.01 ?, c =5.91 ?, α= γ =90.00°, β =101.96°, Z=2 and V =469.10 ?3. The fraction coordinate of each atom in the unit cell is well located and reported. | HU Enping CHENG Qiang GUO Linghong LI Hui | 2006 | Chinese Science Bulletin2006,51,19: | 7 |
| 2 | The Significance of PSA Modified Parameters (F/T)/PSAD for Diagnosing Prostatic Cancer in the Grey Zone of 4~10 ng/ml显示文摘OBJECTIVE To investigate the diagnostic value of modified prostate specific antigen(PSA)parameters in the diagnosis of prostate cancer(PCA) when the serum PSAis in a grey zone of 4~10 ng/ml. METHODS The results of serum PSA determinations of the patients receiving a transrectal ultrasound-guided multiphase prostatic biopsy,were retrospectively analyzed.In the 88 patients with a serum PSA value of 4-10 ng/ml,the final diagnosis of PCA was made in 21,and that of benign prostate hyperplasia(BPH)in 67 patients.The percentage of the free-serum PSA([FPSA]/total-serum PSA[TPSA],F/T),PSA density(PSAD)and the sensitivity and specificity of the new PSA modified parameter(F/T)/PSAD in diagnosing PCA,within a set threshold value,was compared. RESULTS In the 88 patients with serum PSA in the grey zone of 4.0-10.0 ng/ml,there was no significant difference in comparing the TPSA between the 21 PCA patients and 67 BPH patients(P>0.05).However, there was a significant difference in the value of modified PSA parameters, such as F/T,PSAD and(F/T)/PSAD,between the PCA and the BPH groups (P<0.001).As the cut off point-value of the F/T,PSAD and(F/T)/PSAD was set at 0.16,0.15 and 0.8,the diagnostic sensitivity for PCA was 66.7%, 76.2%and 85.7%,and the specificity was 41.8%,43.3%and 68.7%,respectively.There was no significant difference in the sensitivity comparing the modified parameters for diagnosing PCA(P>0.05),whereas an overt predominance was present in the specificity of(F/T)/PSAD for PCAdiagnosis (P<0.05). CONCLUSION In the serum PSA grey zone of 4-10 ng/ml,a modified PSA parameter can improve the PCA diagnostic accuracy rate.With a considerably high sensitivity,application of the(F/T)/PSAD may effectively enhance the diagnostic specificity,which is superior to the F/T and PSAD, and can be expected to be one of the new indices derived from the PSA. | Dongliang Yan Enping Hu Haitao Zhang Sheng Liu Hairong Cai Lei Zhang Yan Zhou | 2007 | Chinese Journal of Clinical Oncology2007,4,5: | 1 |