维普中文期刊产品整合服务
3篇 您的检索式:作者名="HANG Yueming"
    题名 作者 年代 出处 被引量
1Flavonoids in food and their health benefits显示文摘YAO Lthu HANG Yueming SHI J 2004Plant Foods Human Nutriton2004,59,3:1
2Comparative Study on Galvanic-Coupled Intrabody Channel Characteristic Measurement Methods显示文摘The galvanic-coupled intrabody communication(GCIBC)uses the human body as the channel for data transmission.The signal flow through different paths within different measure-ment schemes,resulting in distinct deviations in the experimental results.This method completely uses human body channel to transmit low-power signals,and has good anti-interference perform-ance.However,for a long time,the channel research of GCIBC has not determined a set of recog-nized and accurate measurement methods and standards.However,few researcher analyze the dif-ferences and principles between different measurement methods.This paper aims at three com-monly used measurement methods.Abstract the equivalent schematic diagrams of three measure-ment schemes:direct measurement,using high-precision differential probe and using balun.The sig-nal return paths generated by three measurement methods are analyzed,the impedance matching and energy transmission efficiency are compared.According to the analysis,the empirical expres-sions in different cases are listed.The mechanism between the channel measurement results gener-ated by the set experimental configuration and the comparison experiment is clarified.The compar-ison experiment with complete floating measurement is carried out as a reference to verify the pro-posed opinion.The measurement error caused by different experimental configurations is verified.This study can provide a reference opinions for the experimental error analysis of GCIBC research in the future,and provide suggestions for the selection of experimental configuration.Yangrong Wen Fengjie Lin Yueming Gao Sio Hang Pun Mang I Vai Min Du 2022Journal of Beijing Institute of Technology2022,31,1:0
3A Comparative Study of the Electrodes Gels’Electrical Properties in the Measurement Issues of Intrabody Communication显示文摘Intrabody communication(IBC)technology is becoming progressively more standard-ized due to its low power consumption and high security features incorporated into the third phys-ical layer of the IEEE 802.15.6 standard.Even then,there are still many challenges in normalizing the measurement issues of IBC.A major concern that should not be overlooked is the electrodes in the IBC,especially the popular use of gel electrodes.In the channel measurements,gel electrodes are commonly employed to improve the signal-to-noise ratio and prevent electrodes from falling off.In this paper,a comparative study of the electrical properties of gel was investigated during the measurement of human channel characteristics and to clarify the differences of them.Firstly,the basis of electrostatic field pole plate measurements and electromagnetic theory were introduced to interpretate how the relative permittivity and conductivity of different gels will influence the meas-urement results.Then the in vivo experiments with different gel or dry electrodes were performed to compare the differences induced by the gel.The results indicate that the influence of the gel on the human channel measurement is mainly concentrated below 400 kHz(the attenuation is re-duced by 16.7 dB on average),and the stability of the permittivity and conductivity of the gel has a direct impact on the stability of its measurement of the human channel.This result may provide a meaningful reference for the standardization of electrode usage in IBC.Fengjie Lin Ziliang Wei Jiejie Yang Yangrong Wen Yueming Gao Sio Hang Pun Mang I Vai Min Du 2022Journal of Beijing Institute of Technology2022,31,1:0
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费