维普中文期刊产品整合服务
2篇 您的检索式:作者名="Francesco Pastorelli"
    题名 作者 年代 出处 被引量
1Efficacy and tolerability of high and low-volume bowel preparation compared:A real-life single-blinded large-population study显示文摘BACKGROUND Low-volume preparations for colonoscopy have shown similar efficacy compared to high-volume ones in randomized controlled trials(RCT).However,most RCTs do not provide data about clinical outcomes including lesions detection rate.Moreover,real-life comparisons are lacking.AIM To compare efficacy(both in terms of adequate bowel preparation and detection of colorectal lesions)and tolerability of a high-volume(HV:4 L polyethylene glycol,PEG)and a low-volume(LV:2 L PEG plus bisacodyl)bowel preparation in a real-life setting.METHODS Consecutive outpatients referred for colonoscopy were prospectively enrolled between 1 December 2014 and 31 December 2016.Patients could choose either LV or HV preparation,with a day-before schedule for morning colonoscopies and a split-dose for afternoon procedures.Adequate bowel preparation according to Boston Bowel Preparation Scale(BBPS),clinical outcomes including polyp detection rate(PDR),adenoma detection rate(ADR),advanced adenoma detection rate(AADR),sessile/serrated lesion detection rate(SDR)and cancer detection rate and self-reported tolerability of HV and LV were blindly assessed.RESULTS Total 2040 patients were enrolled and 1815(mean age 60.6 years,50.2%men)finally included.LV was chosen by 52%of patients(50.8%of men,54.9%of women).Split-dose schedule was more common with HV(44.7%vs 38.2%,P=0.005).High-definition scopes were used in 33.4%of patients,without difference in the two groups(P=0.605).HV and LV preparations showed similar adequate bowel preparation rates(89.2%vs 86.6%,P=0.098),also considering the two different schedules(HV split-dose 93.8%vs LV split-dose 93.6%,P=1;HV daybefore 85.5%vs LV day-before 82.3%,P=0.182).Mean global BBPS score was higher for HV preparations(7.1±1.7 vs 6.8±1.6,P<0.001).After adjustment for sex,age and indications for colonoscopy,HV preparation resulted higher in PDR[Odds ratio(OR)1.32,95%CI:1.07-1.63,P=0.011]and ADR(OR 1.29,95%CI 1.02–1.63,P=0.038)and comparable to LV in AADR(OR 1.51,95%CI 0.97-2.35,P=0.069),SDR and cancer detection rate.The use of standard-definition colonoscopes was associated to lower PDR(adjusted OR 1.59,95%CI:1.22-2.08,P<0.001),ADR(adjusted OR 1.71,95%CI:1.26–2.30,P<0.001)and AADR(adjusted OR 1.97,95%CI:1.09-3.56,P=0.025)in patients receiving LV preparation.Mean Visual Analogue Scale tolerability scored equally(7,P=0.627)but a≥75%dose intake was more frequent with LV(94.6%vs 92.1%,P=0.003).CONCLUSION In a real-life setting,PEG-based low-volume preparation with bisacodyl showed similar efficacy and tolerability compared to standard HV preparation.However,with higher PDR and ADR,HV should still be considered as the reference standard for clinical trials and the preferred option in screening colonoscopy,especially when colonoscopy is performed with standard resolution imaging.Vincenzo Occhipinti Paola Soriani Francesco Bagolini Valentina Milani Emanuele Rondonotti Maria Laura Annunziata Flaminia Cavallaro Sara Vavassori Maurizio Vecchi Luca Pastorelli Gian Eugenio Tontini 2021World Journal of Gastrointestinal Endoscopy2021,13,12:4
2Phase control of femtosecond pulses on the nanoscale using second harmonic nanoparticles显示文摘Investigations of ultrafast processes occurring on the nanoscale require a combination of femtosecond pulses and nanometer spatial resolution.However,controlling femtosecond pulses with nanometer accuracy is very challenging,as the limitations imposed both by dispersive optics on the time duration of a pulse and by the spatial diffraction limit on the focusing of light must be overcome simultaneously.In this paper,we provide a universal method that allows full femtosecond pulse control in subdiffraction-limited areas.We achieve this aim by exploiting the intrinsic coherence of the second harmonic emission from a single nonlinear nanoparticle of deep subwavelength dimensions.The method is proven to be highly sensitive,easy to use,quick,robust and versatile.This approach allows measurements of minimal phase distortions and the delivery of tunable higher harmonic light in a nanometric volume.Moreover,the method is shown to be compatible with a wide range of particle sizes,shapes and materials,allowing easy optimization for any given sample.This method will facilitate the investigation of light–matter interactions on the femtosecond–nanometer level in various areas of scientific study.Nicolo Accanto Jana B Nieder Lukasz Piatkowski Marta Castro-Lopez Francesco Pastorelli Daan Brinks Niek F van Hulst 2014Light(Science & Applications)2014,3,1:0
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费