维普中文期刊产品整合服务
3篇 您的检索式:作者名="Eng Gee Lim"
    题名 作者 年代 出处 被引量
1RF characteristics of wireless capsule endoscopy in human body显示文摘The wireless capsule endoscope,as a small electronic device,has conquered some limitations of traditional wired diagnosing tools,such as the uncomfortableness of the cables for the patient and the inability to examine the very convoluted small intestine section.However,this technique is still encountering a lot of practical challenges and is looking for feasible improvements.This work investigates the RF performance of the wireless capsule endoscope system by studying the electromagnetic(EM) wave propagation within the human body.A wireless capsule endoscopy transmission channel model is constructed to serve the purpose of investigating signal attenuations according to the relative position between the transmitter and the receiver.Within 300-500 MHz,the S_(21) results are regular and do not display any sudden changes,which allows a suitable expression to be derived for S_(21) in terms of frequency and offset.The results provide useful information for capsule localization.王璟琛 王炤 Mark Leach LEE Sanghyuk Eng Gee Lim HUANG Yi 2016Journal of Central South University2016,23,5:4
2Boceprevir early-access for advanced-fibrosis/cirrhosis in Asia-pacific hepatitis C virus genotype 1 non-responders/relapsers显示文摘AIM:To examined the efficacy and safety of treatment with boceprevir,PEGylated-interferon and ribavirin(PR)in hepatitis C virus genotype 1(HCVGT1) PR treatmentfailures in Asia.METHODS:The Boceprevir Named-Patient Program provided boceprevir to HCVGT1 PR treatment-failures.Participating physicians were invited to contribute data from their patients:baseline characteristics,ontreatment responses,sustained virological response at week 12(SVR12),and safety were collected and analysed.Multivariate analysis was performed to determine predictors of response.RESULTS:150 patients were enrolled from Australia,Malaysia,Singapore and Thailand(Asians = 86,Caucasians = 63).Overall SVR12 was 61%(Asians= 59.3%,Caucasians = 63.5%).SVR12 was higher in relapsers(78%) compared with non-responders(34%).On-treatment responses predicted SVR,with undetectable HCVRNA at week 4,8 and 12 leading to SVR12 s of 100%,87%,and 82%respectively,and detectable HCVRNA at week 4,8 and 12,leading to SVR12 s of 58%,22%and 6%respectively.Asian patients were similar to Caucasian patients with regards to on-treatment responses.Patients with cirrhosis(n= 69) also behaved in the same manner with regards to on-treatment responses.Those with the IL28 B CC genotype(80%) had higher SVRs than those with the CT/TT(56%) genotype(P = 0.010).Multivariate analysis showed that TW8 and TW12 responses were independent predictors of SVR.Serious adverse events occurred in 18.6%:sepsis(2%),decompensation(2.7%) and blood transfusion(14%).Discontinuations occurred in 30.7%,with 18.6%fulfilling stopping rules.CONCLUSION:Boceprevir can be used successfully in PR treatment failures with a SVR12 > 80%if they have good on-treatment responses;however,discontinuations occurred in 30%because of virological failure or adverse events.Wattana Sukeepaisarnjaroen Tri Pham Tewesak Tanwandee Saroja Nazareth Sam Galhenage Lindsay Mollison Leanne Totten Alan Wigg Rosalie Altus Anton Colman Brenda Morales Sue Mason Tracey Jones Nadine Leembruggen Vince Fragomelli Cheryl Sendall Richard Guan Dede Sutedja Soek Siam Tan Yock Young Dan Yin Mei Lee Widjaja Luman Eng Kiong Teo Yin Min Than Teerha Piratvisuth Seng Gee Lim 2015World Journal of Gastroenterology2015,21,28:0
3Self-Assembled Porous-Reinforcement Microstructure-Based Flexible Triboelectric Patch for Remote Healthcare显示文摘Realizing real-time monitoring of physiological signals is vital for preventing and treating chronic diseases in elderly individuals. However,wearable sensors with low power consumption and high sensitivity to both weak physiological signals and large mechanical stimuli remain challenges.Here, a flexible triboelectric patch(FTEP) based on porous-reinforcement microstructures for remote health monitoring has been reported. The porousreinforcement microstructure is constructed by the self-assembly of silicone rubber adhering to the porous framework of the PU sponge. The mechanical properties of the FTEP can be regulated by the concentrations of silicone rubber dilution. For pressure sensing, its sensitivity can be effectively improved fivefold compared to the device with a solid dielectric layer, reaching 5.93 kPa^(-1) under a pressure range of 0–5 kPa. In addition, the FTEP has a wide detection range up to 50 kPa with a sensitivity of 0.21 kPa^(-1). The porous microstructure makes the FTEP ultra-sensitive to external pressure, and the reinforcements endow the device with a greater deformation limit in a wide detection range. Finally, a novel concept of the wearable Internet of Healthcare(Io H) system for real-time physiological signal monitoring has been proposed, which could provide real-time physiological information for ambulatory personalized healthcare monitoring.Hao Lei Haifeng Ji Xiaohan Liu Bohan Lu Linjie Xie Eng Gee Lim Xin Tu Yina Liu Peixuan Zhang Chun Zhao Xuhui Sun Zhen Wen 2023Nano-Micro Letters2023,15,7:0
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费