维普中文期刊产品整合服务
2篇 您的检索式:作者名="Alan Bulava"
    题名 作者 年代 出处 被引量
1Clinical outcomes of radiofrequency catheter ablation of atrial fibrillation in octogenarians lO-year experience of a one high-volume center显示文摘Background Prevalence of atrial fibrillation (AF) increases with age. Radiofrequency catheter ablation (RFCA) is an establishedtreatment option superior to antiarrhythmics (AAs). In this study, we investigated safety and efficacy of RFCA of AF in octogenarians.Methods From our database, we extracted procedural and follow-up data for patients 〉 80 years with symptomatic AF undergoing RFCAand compared this population to RFCA patients 〈 50 years. All patients underwent pulmonary vein isolation (PVI) supplemented by linearlesions in PVI-nonresponders. Arrhythmia-free survival was assessed using seven day Holter every three months post procedure. All patientscompleted their 12 months follow-up. Results Fifty patients aged ≥80 years (80.5 ± 1.6 years) were compared to 259 patients aged 〈 50years (43.5±5.5 years). The RFCA complication rate did not vary between groups. No differences in procedural characteristics were seenafter being analyzed by type of AF. Among patients with paroxysmal AF, 71.4% octogenarian vs. 84.7% young patients was free of anyarrhythmia, without AAs, after single procedure. For non-paroxysmal AF, arrhythmia-free survival without AAs, was considerably lower(58.6% octogenarians vs. 81.2% younger patients, P = 0.023). If AAs were used, arrhythmia-free survival for paroxysmal AF increased to90.5% and 92.1% in octogenarians and younger patients, respectively; and in non-paroxysmal AF it increased to 79.3% vs. 88.4%. ConclusionsRFCA is a safe and effective strategy to achieve normal sinus rhythm in a highly selected group of octogenarians. Paroxysmal AF ablation inoctogenarians has similar clinical effectiveness as that seen in much younger patients. Non-paroxysmal AF ablation has lower, but still rea-sonable clinical effectiveness.Alan Bulava Jiri Hanis Ladislav Dusek 2017Journal of Geriatric Cardiology2017,14,9:5
2Remote monitoring of implantable cardioverters defibrillators:a comparison of acceptance between octogenarians and younger patients显示文摘Background Remote monitoring(RM)is increasingly employed for all types of cardiac implantable devices(CIED).However,there are only limited data on the acceptance of RM by the elderly.The aim of our study was to ascertain how octogenarians assess RM technologies compared to younger,presumably technically more literate patients,and what concerns or technical problems the system presents to both groups of patients.Methods The trial was designed as a descriptive,register-based single-center study.The study population consisted of all consecutive patients≥80 years of age(group A,n=94)and all consecutive patients aged≤40 years(group B,n=71),who had undergone implantation of an implantable cardioverter-defibrillator(ICD)between the years of 2009 and 2018 and were using a Home Monitoring?(HM,Biotronik,Berlin,Germany)system.All patients fulfilling entry criteria were approached with a request to participate in the survey.Results A total of 85(90.4%)and 65(91.5%)valid surveys were obtained for groups A and B,respectively.Ninety-two percent of patients in both groups(P=0.903)were satisfied with the limited number of planned ambulatory follow-ups(i.e.,once a year).All patients in both groups(100%)reported that they were satisfied with the HM system,and 97%and 94%of patients in Groups A and B,respectively,ranked it highly beneficial(P=0.68).A significant proportion of patients in both groups were completely unaware of any health-related benefits associated with the use of the HM system(42%in Group A vs.49%in Group B,P=0.4).Among the most frequently reported personal benefits of HM were a sense of safety and security and savings on travel expenses and time.5%and 9%of patients in Groups A and B,respectively,reported that usage of HM caused them some degree of psychological stress(P=0.27).Nearly all patients in both groups reported receiving information on HM from their doctor after ICD implantation.None of Group A reported receiving information from a nurse either before or after ICD implantation,while 14%of Group B patients reported receiving information from a nurse after,but not before ICD implantation.Seven and 51%(P<0.0001)of patients in Group A and B,respectively,sought additional information about HM post-discharge.Conclusions The HM system received good marks and was much appreciated,even in patients over 80 years of age.The level of acceptance and potential psychological stress resulting from RM technology appears to be about the same in older patients as in younger patients.The majority of octogenarians either did not fully understand the clinical benefits of the system or mistakenly thought that the HM system was a substitute for emergency 24-h surveillance.These results highlight the need for better patient education relative to RM technology,with one option being to delegate more of this educational process to specially trained nurses.Iva Safarikova Alan Bulava Premysl Hajek 2020Journal of Geriatric Cardiology2020,17,7:0
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费