维普中文期刊产品整合服务
共被期刊论文引用了1次 您的检索式:您选中1篇文献正在查看引证文献汇总
    题名 作者 年代 出处 被引量
1Effects of Different Right Ventricular Pacing Sites on QRS Duration in Patients Receiving Permanent Dual Chamber Pacemakers显示文摘Objective:To investigate the influence of different right ventricular (RV) pacing sites on QRS width, and to provide a potential reference site for permanent right ventricular pacing in patients implanted with permanent pacemakers. Pacing at the site with the shortest QRS duration may reduce the deleterious effects of RV pacing on LV function, and thus having beneficial effects on patient's outcome. Methods: All consecutive patients who were planned to have permanent pacemaker implantation for a ClassI or IIaindication atour departmentfromOctober 2010 toJuly2012 werescreened for the participation in this prospective, single center, non-randomized study. The baseline surface ECG was analyzed for QRS width and morphology, respectively. During the implantation procedure patients were transiently paced at different RV locations(right ventricular apex, right ventricular inflow tract [RVIT], mid septum, high septum and right ventricular outflow tract [RVOT]) before the lead was placed at its final position. During pacing at the different positions the surface 12-leads ECG was recorded. Based on the surface of ECG QRS duration and morphology of the different right ventricular pacing sites were analyzed and compared with baseline and to each other. Results: A total of 216 patients(39% female, mean age 69±13 years, higher degreeAV block 30.5%)wasenrolled in thestudy. Paced QRS duration wassignificantly different between all right ventricular pacing sites compared with the baseline ECG(baseline: 106 ms±21 ms; mean paced: 158 ms±16 ms; p<0.001). RVA pacing showed the widest QRS(168 ms±16 ms). QRS duration with RVIT pacing was 166 ms±15 ms,and that with RVOT pacing was 165 ms±15 ms, respectively. QRS duration was not significantly different between these three positions. Mid-septal pacing showed the narrowest QRS(139 ms±19 ms) compared to all other pacing sites(p<0.001). Pacing at the high-septum showed a broader QRS (153 ms±14 ms) than that pacing at the mid-septum. Compared to other right ventricular pacing sites, QRS morphology at the mid-septum was close to normal, and electrical axis was unchanged as compared to baseline. Conclusion: Pacing at different right ventricular sites showed the significant widening of QRS compared to baseline. The shortest QRS duration was seen with mid-septal pacing. Therefore, mid-septal pacing may have less deleterious effect on LV function compared to other RV pacing locations, which may be the optimal right ventricular pacingsite in permanent pacemaker recipients.REN Xiao-qing CHANG Yu TANG Min FANG Pi-hua WANG Fang-zheng ZHANG Shu Christian G.Wollmann 2014Chinese Journal of Biomedical Engineering(English Edition)2014,23,2:2
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费