维普中文期刊产品整合服务
共被期刊论文引用了3次 您的检索式:您选中1篇文献正在查看引证文献汇总
    题名 作者 年代 出处 被引量
1考虑摩擦因素影响的结合面切向接触阻尼分形预估模型及其仿真显示文摘为准确计入结合面表面微观形貌对结合面的影响,提出结合面的'固-隙-固'接触模型。基于该接触模型和接触分形理论以及赫兹理论,建立考虑摩擦因素影响的结合面切向接触阻尼的分形预估模型,并通过数值仿真研究揭示有关参数对结合面切向接触阻尼的影响,为后续结合面动力学建模和动力学特性分析做准备。仿真分析结果表明:结合面的切向接触阻尼随结合面实际接触面积的增大而增大;随结合面法向载荷的增大而减小;随结合面间摩擦因数的增大而趋于恒定;实际接触面积影响cte*-μ曲线转折点(即临界摩擦因数μc)的位置,随着实际接触面积的增大,临界摩擦因数μc亦同时增大;不同的分形维数取值,尤其是分形维数取值在临界值(D=1.55)的两侧时,结合面间的接触行为存在较大差异。李小彭 王伟 赵米鹊 聂慧凡 闻邦椿 2012机械工程学报2012,48,23:33
2基于微机械电子技术的黏度测量传感器显示文摘黏度作为流体特性的基本问题,在生物化工等诸多工程中是控制生产流程、保证安全生产、进行医学诊断及科学研究的基础性热物数据,为满足各个领域高精度与高效快捷的黏度测量需求,近年来黏度测量手段已不局限于如毛细血管法、旋转法等传统意义的宏观测量方法,基于微纳米尺度的黏度测量技术已展现出其突出的发展与应用前景。微机械电子系统(Microelectromechanical systems,MEMS)技术的蓬勃发展促使黏度测量集成化、智能化与实时性,多样化黏度测量方法不断涌现,其中谐振式黏度测量受到颇为广泛而深入的关注,并显示了瞩目的检测性能。首先回顾传统的黏度测量方法,然后再介绍了基于微机械电子技术的谐振式黏度测量方法,并分别总结了各自的特点。最后,对MEMS谐振式黏度测量方法的发展趋势进行了展望。黄琳雅 赵立波 罗国希 李支康 吴德志 林启敬 杨萍 蒋庄德 2021机械工程学报2021,57,8:4
3Modeling and Analysis of Mechanical Quality Factor of the Resonator for Cylinder Vibratory Gyroscope显示文摘Mechanical Quality factor(Q factor) of the resonator is an important parameter for the cylinder vibratory gyroscope(CVG). Traditional analytical methods mainly focus on a partial energy loss during the vibration process of the CVG resonator, thus are not accurate for the mechanical Q factor prediction. Therefore an integrated model including air damping loss, surface defect loss, support loss, thermoelastic damping loss and internal friction loss is proposed to obtain the mechanical Q factor of the CVG resonator. Based on structural dynamics and energy dissipation analysis, the contribution of each energy loss to the total mechanical Q factor is quantificationally analyzed. For the resonator with radius ranging from 10 mm to 20 mm, its mechanical Q factor is mainly related to the support loss, thermoelastic damping loss and internal friction loss, which are fundamentally determined by the geometric sizes and material properties of the resonator. In addition, resonators made of alloy 3J53(Ni42Cr Ti Al), with different sizes, were experimentally fabricated to test the mechanical Q factor. The theoretical model is well verified by the experimental data, thus provides an effective theoretical method to design and predict the mechanical Q factor of the CVG resonator.XI Xiang WU Xuezhong WU Yulie ZHANG Yongmeng 2017Chinese Journal of Mechanical Engineering2017,30,1:3
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费