共被期刊论文引用了2次
您的检索式:您选中1篇文献正在查看引证文献汇总
|
|
|
题名
|
作者
|
年代
|
出处
|
被引量
|
| 1 | Determination of gold nanoparticles in natural water using single particle-ICP-MS显示文摘A reliable method for detecting nanoparticles is necessary for the wide application of nanomaterials. Single particle-inductively coupled plasma mass spectrometry(SP-ICP-MS) was investigated to detect the size of gold nanoparticles(Au NPs) in this work. Discrimination of particle signal and iterative algorithm were used to calculate the baseline of particle signal. Influence of dwell time was discussed and 3 ms was selected as dwell time for size detection. Different Au NPs standards(30, 60, 80 and 100 nm) and mixed samples(60 and 100 nm) were determined by SP-ICP-MS and the accuracy was confirmed with reference values. The particle size detection limit was 19 nm in ultrapure water(UP water) and 31 nm in 0.1 μg/L Au^(3+) solution. Stability of Au NPs in ultrapure water and natural water samples was investigated by detecting size variation of AuN Ps. The result shows that Au NPs are stable in aqueous environment for 6 d but degraded after 30 d. | 龙晨璐 杨兆光 杨远 李海普 王强 | 2016 | Journal of Central South University2016,23,7: | 1 |
| 2 | Room temperature gas sensor based on tube-like hydroxyapatite modified with gold nanoparticles显示文摘The main goal of this work is to explore the possibility of using Au-modified hydroxyapatite(HA) as a potential sensor material. Tube-like HA structure was fabricated with the aid of a Nafion N-117 cation exchange membrane and gold(Au) nanoparticles were added by a hydrothermal method. The morphology, structure and composition were characterized by scanning electron microscopy(SEM), transmission electron microscopy(TEM), X-ray diffraction(XRD), and X-ray photoelectron spectroscopy(XPS). The gas sensing properties were also investigated. Results show that Au nanoparticles are dispersed into the HA powder, which is tube-like, with rough inner and outer surfaces. Compared with pure HA, Au-modified HA exhibits improved sensing properties for NH_3. 5%(mass fraction) Au-modified HA shows the highest response with relatively short response/recovery time. The response is up to 79.2% when the corresponding sensor is exposed to 200×10^(-6) NH_3 at room temperature, and the response time and recovery time are 20 s and 25 s, respectively. For lower concentration, like 50×10^(-6), the response is still up to 70.8%. Good selectivity and repeatability are also observed. The sensing mechanism of high response and selectivity for NH_3 gas was also discussed. These results suggest that Au-HA composite is a promising material for NH_3 sensors operating at room temperature. | 罗兰兰 刘咏 谭彦妮 李会霞 张青 李昆 | 2016 | Journal of Central South University2016,23,1: | 0 |
      /1